Selection Guide

Canada: 452 Attwell Drive, Etobicoke, ON M9W 5C3 tel: 416.679.0045 • fax: 416.679.0051
U.S.A : 20 Commerce Park North, Bedford, New Hampshire 03110 tel: 603.669.5136 • fax: 888.889.3539 • 800.654.5600
rev 30.11.2021
® ®
Z-VENT
®
Suggested Appliance Adaptors*
Page 19
» Information subject to change without notice.
» Consult appliance manufacturer for additional information regarding Z-VENT
®
approvals of vent
and or air for U.S. and or Canada.
» Support vent and air piping within 1ft of appliance adaptors to avoid applying weight to these connections.
» Install carbon monoxide detector and alarms in accordance with local codes.
» Z-VENT
®
, Z-VentBlu
®
and NovaVent
®
are all UL1738 & ULC-S636 listed under UL file MH18505 and all utilizes the
appropriate Z-VENT
®
adaptor.
» Contact Z-Flex
®
U.S. Inc. at (800) 654-5600 if there is any concerns with suggested adaptor, or if you
require any additional information.
DESCRIPTION PART NUMBER
Connects 3" Z-Vent
®
to Safety Vent co-axial vent termination 2SVSSVA03
Connects Z-Vent
®
to Slant-Fin’s horizontal vent termination(part # 665-191) 2SVSSLA1
**Z-Vent
®
Sealant high temperature silicone sealant required to adapt some pipe to certain flues 2SILRRTV106X
Appliance with CPVC/PVC Coupling to Z-Vent
®
2SVSACPVC(3,4,6,8)
Appliance with CPVC/PVC Pipe to Z-Vent
®
2SVSACPVCF(3,4,6)
Appliance with Gasket & Clamp for CPVC/PVC Pipe x 2" Long Male to Z-Vent
®
2SVSTTA(023,03,04.5,06)
Appliance with Gasket & Clamp for CPVC/PVC Pipe x 4" Long Male to Z-Vent
®
2SVSPVC(03,04,06)
Appliance with SafTVent to Z-Vent
®
2SVSHF(03,04,05,06,07,08,09,10,12)
Appliance with FasNSeal to Z-Vent
®
2SVSAFNS(03,04,05,06,07,08,09,10,12,14)
Z-DENS to Z-Vent
®
2ZD2ZV(3,4,6,8)
Z-Vent
®
to Z-DENS 2ZDZV(3,4,6,8)
The information provided within is for informational purposes only. We have made every effort to ensure the accuracy of the provided information and assume no responsibility for any loss or
damage due to errors or omissions or to the use or misuse of any information supplied. It is impossible to test all products under all conditions to which they might be subjected in the field. It is
therefore the buyer and/or end users’ responsibility to test all products under the conditions that duplicate the service conditions prior to installation. All improvements, all specifications are subject
to change without prior notice. It is the buyer and/or end users’ responsibility to review our complete Terms and Conditions of Sale located on our web sites at:
www.novaflex.com | www.z-flex.com | www.flexmaster.com.