User`s manual
ZPrint™ Software Manual Advanced Settings
zcentral.zcorp.com 77 All Rights Reserved
11/30/09
8.5.4 Fixtures Tab
Preferences – Fixtures Tab
These are the default settings for generating
Fixtures. See Section 5.22 “Default Fixture
Settings” for more information.
Max Top Thickness: The maximum thickness of the top
surface.
Min Top Thickness: The minimum thickness of the top
surface. The lower this value is, the better the
fixture will cradle the part.
Wall Thickness: Sets the thickness of the Fixture wall.
Distance between walls by X: The distance between
the Fixture walls in the X direction.
Distance between walls by Y: The distance between the
Fixture walls in the Y direction.
Base Grid Thickness: Determines how high the part is
moved from the bottom of the build box to accommodate
the fixture base.
Accuracy coefficient: Set the value for separating the
part and the fixture for parts that have vertical, or nearly
vertical, walls. The smaller the degree of separation, the
better the fixture will follow the shape of the part. Run
Collision Detection to see if the fixture is touching the
part. If it is, increase the Accuracy Coefficient by a small
amount and rerun Collision Detection.