6.9 Bleed Air
‘Bleed Air’ moves the carriage to the front of the Spectrum allowing easy access to the carriage.
Bleed air should be performed on initial machine setup and whenever air enters into he binder
fluid lines. Air in the binder fluids system will cause premature print head death.
1. Select ‘Bleed Air’ under the
Service menu.
2. Open carriage cover and remove
print heads.
3. Use syringe (found in toolbox) to
draw water through each fluid
line. Draw fluid through each line
until it is clear (minimum of 50
cc).
4. Close carriage cover, and top
cover, and ‘Cancel’ in the
software.