3-4-1. Alarm-Out
Table 3.4.2. Menu Item in Alarm-Out Setup Screen
Item Description
ALARM OUT
Only 1 output
SENSOR IN
Enable setting up to 4 sensors out of 16 channels.
MOTION ON
Enable setting up to 4 cameras out of 16 channels.
VIDEO LOSS ON
Enable setting up to 4 cameras out of 16 channels.
ALARM DURATION
Set the dwell time of alarm from 3 to 255 seconds.
Alarm-Out Setup Screen
3-4-2. PTZ Setup
To control the PTZ functions of the camera, connect the controller to the RS-485 port.
For speed dome cameras that supports RS-485, connect them directly to the RS-485 port. If the PTZ is controlled
via RS-232C, a Signal Converter (RS-485 to RS-232C) is a necessary.
In the PTZ Control setting in the setup menu, user can select or set the protocol type of the camera which is the
same as the one that is installed on the site. If the camera has a specific camera ID, select the camera ID by using
<Left> or <Right> button.
PTZ Setup Screen Menu Item in PTZ Setup Screen
Item Description
CH
Channel number that the PTZ is
connected to
NAME
Protocol type
SPEED
19200, 14400, 9600, 4800, 2400
ID
0-63