Owner`s manual
General Information
D-011-0152 11
Console Connections
Figure 5 shows the EA800 console's connections and Table 3 describes the functions of each connection.
Note: The console has four wired sensor inputs and four wireless RF sensor inputs.
Figure 5 EA800 Console Connections
MENU key: Displays the MAIN MENU screen when pressed from any menu level or
from the home screen.
SILENCE key: Alarms cannot be cleared and will continue to recur until the moni-
tored conditions detected by the sensors are within the programmed parameters.
Pressing the SILENCE key temporarily silences the local audible alarm and deacti-
vates the auxiliary relay for 10 minutes.
If a new alarm originating from a different sensor occurs within this 10-minute
period, the audible alarm and aux relay are reactivated, and require another key
press to silence the audible alarm.
Table 2 Key Functions — continued
Power
In
Aux
Power
Out
J6
J5
Input 1 Input 2 Input 3 Input 4
J13
J14
J2
J10J8 J9
Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Aux
NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC NO COM NC
Wired Inputs