Datasheet

SPECIFICATION FOR APPROVAL
1. PHYSICAL DIMENSIONS:(mm)
PART NAME
MODEL NO
TO:

EMI FILTER
YR06A3
OUR DRAWING NO
SAMPLE DATE
CK002 30101
CK002 30101
EMI FILTER
SPECIFICATION FOR APPROVAL
3.ELECTRICAL CHARACTERISTICS:
3-1.RATED VOLTAGE 125/250VAC
3-2.RATED CURRENT 6 A
3-3.OPERATING FREQUENCY 50/60Hz
3-4.LEAKAGE CURRENT:EACH LINE TO GROUND
250VAC 50Hz 0.8mA MAX
3-5.HIPOT RATING.(FOR ONE MINUTE)
LINE TO LINE 1450VDC
LINE TO GROUND 1800VAC
3-6.INSULATION RESISTANCE 250VDC/100MOHM MIN
3-7.DIRECT CURRENT RESISTANCE 0.15 OHM MAX
3-8.OPERATING TEMPERATURE -25 TO +85 C
PART NAME
MODEL NO
YR06A3
OUR DRAWING NO
SAMPLE DATE
2/2
CX : 0.1uF
CY : 3300pF20%
L : 2X0.7mH
2. SCHEMATIC:


R2 MAX


28.7MAX
39.2
SUGGESTED CUTOUT
MOUNTING DIMENSIONS
OF SOCKET
1/2
CHECKED BYREPORTED BY
APPROVED BY
REV. 4
6
5


NOV.11.2013
YDR-00360d
4..SAFETY COMPLIANCE:
UL FILE NO:E134751
VDE FILE NO:40028561
CQC FILE NO:12001067993
CE
G
LINE
2
1
CX L
G
CY
4
CY
3
LOAD
REV. 1
2
APPROVED BY
REPORTED CHECKED BY
BY
3
+0.1
-0.2
JUN.24.2013
YDR-00360d
FTB-5557
FTB-5557
TO: 
5. INSERTION LOSS IN dB:
0.15MHZ 0.5MHZ
1MHZ
5MHZ 10MHZ 30MHZ 50MHZ
common mode
normal mode
ABOVE TABLES ARE REFERENCE ONLY.
FREQUENCY
INSERTION LOSS
43 41 36
46
51
48
46
8
17 21
32
33
36
46