User manual

17
4.4 CAMERA SETUP
or to change item
or to change value
A. CAMERA
By or to change camera channel.
B. DISPLAY
By or to change value for this camera would display on screen or not.
C. RECORD
By or to change value for this camera would include with the recording or
not.
D. BRIGHTNESS
By or to change brightness level.
E. CONTRAST
By or to change contrast level.
F. HUE
By or to change HUE level.
G. COLOR
By or to change color level.
H. CAMERA TITLE
By or to switch item & by or to change wording.
4.5 MOTION SETUP
or to change item
or to change value
A. CAMERA
By or to change value for camera motion setup.
B. MOTION DETECT
By or to change value for motion detect function.
C. BUZZER
By or to change value for buzzer or not while motion detected.
D.SENSITIVITY
By or to change sensitivity value from 001 (min) to 100 (max).
E. AREA SETUP
Press ENTER key to enter motion area setting.
1. Press direction key to select which block need to change.
2. Press AUTO to add a line to motion detection.
3. Press SEL to remove a line to motion detection.
4. Press MENU key to quit motion detection area setup.
CAMERA SETU
P
CAMERA CAM 01
DISPLAY ON
RECORD ON
BRIGHTNESS 50
CONTRAST 50
HUE 50
COLOR 50
CAMERA TITLE 01
EXIT
MOTION SETU
P
CAMERA CAM 01
MOTION DETECT ON
BUZZER OFF
SENSITIVITY 080
AREA SETUP [<]
EXIT