Datasheet

Poltypen Terminals
7
NP Entladecharakteristik bei 20°C
Spezifikationen – Specifications
Minuten
minutes
Stunden
hours
(V)
Für/for 12V
Batterien/batteries
(V)
Für/for 6V
Batterien/batteries
A
B
C
DE
JST SVH-21T-P1.1
Kabel: AWG # 20 UL 1007
x
17 mm
20 mm
y z
M5 x 10
M6 x 16
Nm
2-3
4-5.5
NP Discharge Characteristic Curves at 20°C
Abmessungen – Dimensions
6
8
Capacity Selection Chart
Entladekapazität
NP24-12
NP17-12
NP38-12
NP65-12
NP0.8-12
NP1.2-6
NP1.2-12
NP1.2-6
NP1.9/2.1-12
NP2.8-6
NP2.8-12
NP3-6
NP4-6
NP4-12
NP6-12
NP7-12
NP10-6
30 40
20
10
8
6
4
3
2
60
40
30
20
10
8
6
60 80 200100 300 400 600 800 1000 2 3 4 6 8 10 20 30 40 60 80 100 200
mA A
20°C
65Ah
38Ah
24Ah
17Ah
12Ah
7.0Ah
6.0Ah
4.0Ah
3.0Ah
2.8Ah
1.9Ah
1.2Ah
1.0Ah
0.8Ah
10Ah
13.0
12.0
11.0
10.0
9.0
6.5
6.0
5.5
5.0
4.5
8.0
4.0
124681020406024681020
3CA
0.6CA
1CA
2CA
0.4CA
0.2CA
0.1CA
0.05CA
20°C
Minuten/minutes
Stunden/hours
Entladestrom/Discharge currentEntladestrom/Discharge current
Polabstände – Terminal Design
C
12
12
22
23
D
43
40
19
30
NP
17 – 12
24 – 12
38 – 12
65 – 12
z
M5
M5
M5
M6
Gewinde/
Thread
2.1Ah
NP12-6
5
YUASA Battery (EUROPE) GmbH