Datasheet

YUASA Battery (EUROPE) GmbH
Wanheimer Straße 47, DE-40472 Düsseldorf, Germany
Tel. +49-211-41790-0, Fax: +49-211-41790-11
e-mail: info@yuasa-battery.de, www.yuasa.de
NPW45-12 neu.doc Revisionsstand: 0 Seite 2 von 3
The battery at time of delivery shall read 12.6 V (OCV) or more at 25°C ±10°C,
provided it is measured within 14 days after delivery.
6.4 Internal resistance:
Give a full charge to the battery, and measure with AC Bridge (1 kHz test frequency)
the reading shall be less than 24 m.
6.5 Capacity retention:
The remaining capacity of the battery, left standing for 3 months at 25°)C shall
be more than 80%. After 6 months it shall retain more than 60% capacity.
6.6 Characteristics against given load:
No deterioration shall be found with 42 A continuous discharge.
No deterioration shall be found with 105 A discharge for 5 seconds.
6.7 Charging recommendations:
Method Given Voltage Charge Current
(Maximum)
Conditions
Standby,
Float
charge
13,65 V ± 0,15 V
No limit When temperature is less than 5°C or
greater than 35°C, temperature
compensation of
–3mV/°C/cell shall be applied with 25°C
as reference point.
Cyclic
charge
14,4 V ~ 15,0 V 1,75 A When temperature is less than 5°C or
greater than 35°C, temperature
compensation of
–4mV/°C/cell shall be applied with 25°C
as reference point.
6.8 Permissible temperature range:
Conditions Temperature range
Discharging
Charging
Storage
-15°C ~ 50°C
C ~ 40°C
-15°C ~ 40°C
6.9 Storage period without use:
Storage temperature Maximum storage period
Less than 25°C 6 months
Less than 30°C 4 months
Less than 35°C 3 months
Less than 40°C 2 months
6.10 Design life (at 20°C)
(1) Cycle life:
Discharge at 1.75 A for 2 hours. Charge at 14.4 V for 16 hours.
Final discharge voltage at the 200th cycle shall be 10.2 V or more
(2) Standby, float charge:
(a) Charge at 13.65 V (±0.15V) continuously and discharge at 1.75 A to
Final Voltage 10.2 V every 3 months. The battery shall last minimum 3
years until capacity falls to 2 hours.