Manual

YSI 5X00
233
YSI 5X00
232
Appendix 5 Parts and Accessories
Replacement Part Part Number and Description
Galvanic probe/cable assemblies
cable lengths available: 4m, 10m, 20m, 30m, and custom to 100 m
p/n 5420-X (X=cable length; galvanic DO
probe cable assembly)
p/n 5421-X (X=cable length; galvanic and
temperature probe cable assembly)
Polarographic probe/cable assemblies
cable lengths available: 4m, 10m, 20m, 30m, and custom to 100 m
p/n 5422-X (X=cable length; polarographic
and temperature probe cable assembly)
Polarographic replacement sensor
p/n 605203 - installs on 5422-X probe cable
assembly
DO Membranes for Galvanic DO Sensor
2 mil Teon 5405-5 membrane kit contains:
-5 membrane
-electrolyte solution
2 mil Teon 5405-25 membrane kit contains:
-25 membranes
-electrolyte solution
Electrolyte solution 5406, 1 pint
DO Membranes and electrolyte solution for Polarographic sensor
2 mil PE (blue) 605307 membrane kit contains:
-6 cap membranes
-electrolyte solution
-sanding disk
-3 gaskets
2 mil Teon (gray) 605204 membrane kit contains:
-6 cap membranes
-Probe electrolyte
-sanding disk
-3 gaskets
Parts & accessories
Replacement Part Part Number and Description
ODO probe/cable assemblies and replacement sensor cap
cable lengths available: 1m, 4m, 10m, 20m, 30m, and custom to 100 m
626250-X (X=cable length; ODO probe cable
assembly)
626320 Replacement Sensor Cap
Installation Mounting kits
Panel mount kit 006510 - for mounting 5200A instrument to
a panel.
Rail mount kit 006509 - for mounting a 5200A instrument to
a rail.
Weather shield kit 006505
Other
AC Power cord, 115 VAC, USA plug 605880, for AC version only, included with
AC version
Adapter, DB-9 to RJ-45 655383, included with instrument
AquaManager Soware, single and
network use
655363
Compression Plugs, Large 605230, 2 each included with instrument
Compression Plugs, Large 605229, 2 each included with instrument
Compression Plugs, Medium 605898, 3 each included with instrument
Compression Plugs, Small 605804, 4 each included with instrument
Conduit ttings 065926UL - For optional conduit mount,
industrial encapsulant required
Conduit Sealer 065921, industrial encapsulant require for
above item
Desiccant pack replacement 006506, included with instrument
DO (Galvanic) sensor reconditioning
kit
5407
DO (Polarographic) sensor recondi-
tioning kit
052380, includes 400 grit sanding discs and
sanding tool.
Dual Male, RJ-45 Cable Assembly 655384, included with instrument
Flange Mounting Kit 006515, included with instrument
Grounding Screws 605889, included with instrument
Pluggable Socket Connector for AC
power, 3 pole
605944UL, for AC version only, included with
AC version
Parts & Accessories