User Manual
YSI 5200A
124
YSI 5200A
125
Press1.
to toggle relay on.
Press2.
to toggle relay o.
Press
3. to save conguration and return to Run Screen.
Note:
Timer and control icon(s) remain on the Run Screen until the system is -
reset. Example - the timer icon remains at the systemwide location until
the end of the timer cycle that was stopped when the relay test menu was
entered even though that relay is not energized. To reset systems aer
exiting the Relay Test menu, power cycle the 5200A.
Service Hold
Menus → System → Service Hold
Pressing
at the Run Screen puts the 5200A into Service Hold. e Service
Hold time is user selectable (1-255 sec, min, or hours). Service Hold turns o any
active relays and disables any sensor, aux, and timer system relays from energizing
regardless of value or condition. 5200A alarm emails are not sent during service
hold. Aer the service hold time expires or is cancelled, sensor systems are reset
aer 30 seconds. Timer systems are not reset.
Use1.
▲
and
▼
to scroll and highlight submenus.
Conguring the 5200A
Press
2.
to select.
Enable and congure submenus.3.
Press4. to save conguration and return to Run Screen.
Version
Menus → System →Version
e Version menu contains information about the 5200A including: display and
control board rmware code version, control board temperature, and AC and DC
voltage.
Notes:
Firmware version information is required when contacting YSI sup- -
port.
e clock chip temperature range starts at 0 - C. Values < 0C are not valid
numbers.
Firmware date and time compilation are displayed below the version -
number.
e normal operating temperature range will be a few degrees above -
ambient.
AC powered units will run at a higher temperature than DC powered -
units.
- To view current AC and DC power values press to return to the
Run Screen and then return to the menu. Power information does not
refresh when the Version menu is open.
AquaManager and the System Menu
AquaManager users can congure most 5200A system menus from a PC. Aer poll-
ing the 5200A, use “Systems Management” from the node window to view and upload
5200A congurations. System menus are congured at the Setup and Input tabs.
Conguring the 5200A