User`s manual

63
This series of limit switches is made up of a case
containing a worm screw unit and micro-switches. ]t is
directly driven by the rope drum axle to which it is
connected by means of a plastic coupling or an hexagonal
shaft.
Removing the cover the cams of the micro-switches can
be seen.
The cam can be released by loosening the central screw;
with lateral screws 1 - 2 - 3 place the cams in the exact
position for opening the contact relative to the two working
directions.
Re-tighten the central screw and carry out a few lifting
manoeuvres as a final test. If there is a cam for the
emergency contact, which acts on the line contactor
switch, there should be a slight delay compared to the
"hoist" contact.
The contacts must be set in the following order;
emergency, "hoist" and then "lower".
Make sure the central screws are tight and then carefully
shut the case.
SETTING OF THE "TER" TYPE WORM SCREW HOIST LIMIT SWITCHES
(To be carried out by a qualified operator)
SETTING OF THE “BOX 0A” TYPE WORM SCREW HOIST LIMIT SWITCH
(to be carried out by a qualified operator)
For setting operations, please refer to the instructions for TER type limit switch
Central screw
Screws open
E
Emergency micro switch
S “Hoisting” micro switch
D “Lowering” micro switch
S hoisting contact
D lowering contact
S
D
1
2
CAMS