User`s manual
42
MAINTENANCE
To ensure good, long-lasting service, suitable maintenance on the various electromechanical parts of the machine is
essential.
The maintenance intervals given in the enclosed table apply to machinery working indoors in normal climatic conditions for an
average working cycle during which normal loads are lifted (rarely maximum load).
When the machine is outdoors, or only under a protective roof, or exposed to the elements or to a saline atmosphere it is
necessary to intensify maintenance, up to reducing normal intervals by half.
Pay attention to the following instructions:
• Cut off the power supply by means of the main isolating switch
• Employ specially appointed skilled personnel only
• Comply with the maintenance intervals given in the table, shorten them for particularly intensive work cycles or if work
is carried out in severe environmental conditions (see paragraph above)
• Follow the procedures given in our instructions
• Only use original spare parts to replace worn ones
• Always keep the machine clean using suitable products
• Observe the life working limit and carry out a complete service on its expiry
• Our company is ready to help or advise you at any time, and provide personnel to carry out maintenance duties.
TABLE
OF
LUBRICATING
OILS
OF
THE
MOST
IMPORTANT
BRANDS
* OIL for ambient temperatures <-10
0
C SPARTANS EP220
>80
0
C GLYCOLUBE Range 220
* GREASE for ambient temperatures <-10
0
C (mm -54) BEACON
> 80
0
C (max 120) BEACON
Lubricants, solvents and detergents are toxic/injurious to health:
• They may cause irritation if put in direct contact with the skin.
• If inhaled they may cause serious intoxication.
• Swallowing them may result in death.
• They must be handled with care, using adequate personal protective equipment (e.g. gloves)
• Do not disperse in the environment. Dispose of as toxic/injurious waste in compliance with local and national
regulations.