User`s manual
23
PREPARATION
OF
RESIN
MIXTURE
FOR
“A”
TYPE
CABLE
GLANDS
Warning! To prevent resin from hardening inside the mixing nozzle (max. 15 minutes), make sure all cable
glands are ready for sealing.
How to proceed:
• A Press lever 1 and pull out plunger 2
• B Twist the cartridge holder
• C Insert cartridge
• D Remove protective cap from 3 cartridge
• E Insert mixing nozzle 4
•
F Pull trigger 5 only when cable glands are ready for sealing
WARNING: ALL THE CABLE GLANDS WITH THE FOLLOWING WARNING TAG HAVE TO BE SEALED UP BEFORE THE
COMMISIONING OF THE DEVICE ON WHICH THEY ARE ASSEMBLED. FAILURE TO COMPLY WITH THE INSTRUCTIONS,
WITH PARTICULAR REFERENCE TO RESIN POURING, AFFECTS THE EXPLOSION-PROOF QUALITY OF THE COMPONENT
AND RELIEVES
ITALKRANE
s.r.l
. FROM ANY AND ALL LIABILITIES FOR ANY POSSIBLE RESULTING DAMAGES.