Yotta 3 SAS/SATA JBOD Enclosure User Guide Ver : 1.
Preface C Cooppyyrriigghhtt 22001111 All rights Reserved- Printed in Taiwan N Noottiiccee We make no warranties with respect to this documentation either express or implied and provide it "as it". This includes but is not limited to any implied warranties of merchantability and fitness for a particular purpose. The information in this document is subject to change without notice. We assume no responsibility for any errors that may appear in this document.
Hardware Operation Manual R Reegguullaattoorryy iinnffoorrm maattiioonn For Europe This drive is in conformity with the EMC directive. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Those limits are designed to provide reasonable protection against harmful interference in a residential installation.
G Geenneerraall SSaaffeettyy G Guuiiddeelliinneess DO NOT place the JBOD System on uneven or unstable work surfaces. Seek servicing if the casing has been damaged. DO NOT place or drop objects on top of the JBOD System and do not shove any foreign object into it. DO NOT expose JBOD System to liquids, rain, or moisture. DO NOT expose JBOD System to dirty or dusty environments. DO NOT expose JBOD System to magnetic field.
Hardware Operation Manual About your User’s Guide Welcome to your Hardware Installation Guide. This manual covers everything you need to know in learning how to install your JBOD system. This manual also assumes that you know the basic concepts of JBOD technology.
Table of Contents PREFACE .................................................................................................2 COPYRIGHT 2011...................................................................................2 NOTICE ..................................................................................................2 TRADEMARKS ........................................................................................2 REGULATORY INFORMATION .........................................................
Hardware Operation Manual LSD – List Devices Status..............................................................68 RESET - System Software Reset.....................................................71 SHOWLOGS - Print System Log. ..................................................71 CLEARLOGS - Print System Log. .................................................72 FDL - File DownLoad ...................................................................72 APPENDIX B .............................................
Chapter 1 Introduction This chapter introduces the features and capabilities of JBOD System.
Hardware Operation Manual Y3-12/16/24S6TS6: Dual SAS Expander Supports SAS & NL SAS 6Gb disk drives. Support SATA 6Gb disk drives with SAS Bridge Board (optional). One 4x 6Gb wide-port SAS connectors for host connection. /per SAS Expander Two 4x 6Gb wide-port SAS connectors for expander module daisy chain. /per SAS Expander Redundant and Hot Swappable SAS Expander, Fan, Power and Drives. Completely monitored by In-band SES.
B Beeffoorree yyoouu bbeeggiinn Unpacking & Checking The Equipment Before unpacking the JBOD SYSTEM, prepare a clean, stable surface to put the contents of your JBOD SYSTEM shipping container.
Hardware Operation Manual SAS to SAS/SATA JBOD System (Rack-mount, SAS Expander x 1) Y3-12S6JS6 : 12 Bay JBOD System x 1 JBOD system Hardware User Guide (CD media ) RS232 cable x 1 SFF-8088 Mini SAS to SFF-8088 Mini SAS Cable x 1 Power Cord x 2 HDD tray x 13 Mounting screws (bag) ×1 Y3-12S6AS6 : 12 Bay JBOD System x 1 JBOD system Hardware User Guide (CD media ) RS232 cable x 1 SFF-8088 Mini SAS to SFF-8088 Mini SAS Cable x 1 Power Cord x 2 FAN x 1 HDD tray x 13 Mounting screws
SAS to SAS/SATA JBOD System (Tower, SAS Expander x 1) Y3-12S6JS6-D : 12 Bay JBOD System x 1 JBOD system Hardware User Guide (CD media ) RS232 cable x 1 SFF-8088 Mini SAS to SFF-8088 Mini SAS Cable x 1 Power Cord x 2 HDD tray x 13 Mounting screws (bag) ×1 SAS to SAS/SATA JBOD System (Rack-mount, SAS Expander x 2) Y3-12S6TS6: 12 Bay JBOD System x 1 JBOD system Hardware User Guide (CD media ) RS232 cable x 2 SFF-8088 Mini SAS to SFF-8088 Mini SAS Cable x 2 Power Cord x 2 HDD tray x 1
Hardware Operation Manual Power Cord x 3 FAN x 1 HDD tray x 25 Mounting screws (bag) ×1 13
What else you need Hard disk drives (Different JBOD model requires different numbers of HDDs). Host computer with SAS interface or Host RAID System with SAS interface Static grounding strap or electrostatic discharge (ESD) safe work area Dedicated terminal or PC with third party communication software that supports ANSI terminal emulation (required for viewing Monitor Utility) The hard drives in a JBOD system should match in size and speed.
Hardware Operation Manual IIddeennttiiffyyiinngg PPaarrttss ooff tthhee JJB BO OD D ssyysstteem m The illustrations below identify the various parts of the JBOD SYSTEM.
Y3-16S6JS6 / Y3-16S6TS6 Y3-12S6JS6 / Y3-12S6TS6 / Y3-12S6AS6 16
Hardware Operation Manual 1. Power On Indicator (Blue). 2. Host System Access Indicator (Blue + blink). 3. Power Fail Indicator (Red) 4. Fan Fail Indicator (Yellow) 5. Over Temperature Indicator (Yellow) 6. Cartridge Handle 7. Lock & Release-Button 8.
Y3-12S6JS6-D 18
Hardware Operation Manual 1. LCD Display Panel The front panel LCD continuously displays the status of the JBOD system. The following is an example of the JBOD system. 2. Power On Indicator (Blue). 3. Power Fail / FAN Fail / Over Temperature Indicator (Red) 4. A Host System Access Indicator (Blue + blink). 5. Function keys.
Rear View Y3-24S6JS6 Y3-24S6TS6 20
Hardware Operation Manual 1. SAS CH 1/E (Expand out 2) 2. SAS CH 0 (Expand In) 3. SAS Expand Port (Expand out 1) 4. Terminal 5. Controller Box 1 6. Controller Box 2 (Reserved for SAS Expander 2) 7. FAN failure indicator (Rear / Front) 8. FAN Module 1 9. FAN Module 1 Latch 10. Power Switch 11. FAN failure indicator (Rear / Front) 12. FAN Module 2 13. FAN Module 2 Latch 14. AC inlet 1 & Latch 15. Power Module 1 16. AC inlet 2 & Latch 17. Power Module 2 18. AC inlet 3 & Latch 19. Power Module 3 20.
Y3-16S6JS6 Y3-16S6TS6 22
Hardware Operation Manual 1. SAS CH 1/E (Expand out 2) 2. SAS CH 0 (Expand In) 3. SAS Expand Port (Expand out 1) 4. Terminal 5. Controller Box 2 (Reserved for SAS Expander 2) 6. Controller Box 1 7. FAN failure indicator (Rear / Front) 8. FAN Module 1 9. FAN Module 1 Latch 10. Power Switch 11. FAN failure indicator (Rear / Front) 12. FAN Module 2 13. FAN Module 2 Latch 14. AC inlet 1 & Latch 15. Power Module 1 16. AC inlet 2 & Latch 17. Power Module 2 18.
Y3-12S6JS6 Y3-12S6TS6 24
Hardware Operation Manual 1. Power Module 1 2. AC inlet 1 & Latch 3. FAN Module 1 4. FAN failure indicator (Rear / Front) 5. Power Switch 6. FAN Module 2 7. FAN failure indicator (Rear / Front) 8. Power Module 2 9. AC inlet 2 & Latch 10. SAS CH1/E LED Indicator (Link / Access) LED SAS Colors Green Blue + Blink Indicate Link Access 11. SAS CH 1/E (Expand out 2) 12. SAS CH 0 (Expand In) 13. SAS CH0 LED Indicator (Link / Access) 14. SAS Expand Port (Expand out 1) 15.
Y3-12S6AS6 1. Terminal 2. SAS Expand Port (Expand out 1) 3. SAS CH 0 (Expand In) 4. SAS CH 1/E (Expand out 2) 5. FAN Module Latch 6. FAN Module 7. FAN failure indicator (Rear / Front) 8. Power Module 2 9. Power Module 1 10. AC inlet 2 & Latch 11. AC inlet 1 & Latch 12. Power Switch 13. SAS CH1/E LED Indicator (Link / Access) LED SAS Colors Green Blue + Blink Indicate Link Access 14. SAS CH0 LED Indicator (Link / Access) 15.
Hardware Operation Manual Y3-12S6JS6-D 1. FAN Module 2. FAN failure indicator 3. AC inlet 1 4. Power Module 1 5. Terminal 6. SAS Expand Port (Expand out 1) 7.
8. SAS CH 0 (Expand In) 9. SAS CH0 LED Indicator (Link / Access) 10. SAS CH 1/E (Expand out 2) 11. SAS CH1/E LED Indicator (Link / Access) 12. AC inlet 2 13. Power Module 2 14.
Hardware Operation Manual SSppaaccee R Reeqquuiirreem meenntt When selecting a location for your system, be sure to allow an adequate space. The system has vents around it which requires a minimum of 3 inches of unobstructed space for airflow. Openings in the equipment should be blocked, or there may be an issue of reliability problems with your system. A system product should never be place around a radiator or heat register.
IInnssttaallll hhaarrdd ddiisskkss The JBOD SYSTEM includes 12/16/24 (depending on your models) removable disk cartridges. The following sections describe how to install disks into JBOD SYSTEM subsystems. Remove Cartridges We designed the lock/unlock mechanism on a same button and called EzSecurLock . No need a key but with security .
Hardware Operation Manual Install HDDs. 1) Put HDD into the Cartridge. 2) Align 4 screws holes on both HDD & Cartridge. 3) Fasten all 4 screws to mount HDD in the cartridge and make sure the HDD is properly tightened. Install Cartridges Reversed the procedures of “Remove cartridges” to install cartridges back to JBOD system. When using Redundant Controller, it is required to install SAS & NL SAS HDDs.
Chapter 2 Hardware Installation This chapter presents: IInnssttrruuccttiioonnss iinn rreeppllaacciinngg ccoom mppoonneennttss I n s t r u c t i o n s i n r e p l a c i n g t h e Instructions in replacing the hhoott ssw waappppaabbllee ccoom mppoonneennttss R Reeppllaaccee tthhee JJB BO OD DC Coonnttrroolllleerr Read the replacing notices in this chapter before proceeding with replacement.
Hardware Operation Manual Removing the controller from Y3-12/Y3-16/Y3-24 series Y3-24S6JS6 / Y3-24S6TS6 1: 1-1.) Disconnect the host cables 1-2.) Turn anti-clockwise to release the thumb screw. 1-3.) Use the eject kit to remove controller board. 2: Slide it back and lifting off Y3-16S6JS6 / Y3-16S6TS6 Installing the controller into Y3-16S6JS6 / Y3-16S6TS6 (Y3-24S6JS6 / Y3-24S6TS6) Reverse the procedures as above to install the controller into Y3-16S6JS6 / Y3-16S6TS6 (Y3-24S6JS6 / Y3-24S6TS6).
Y3-12S6JS6 / Y3-12S6TS6 1: 1-1.) Disconnect the host cables 1-2.) Turn anti-clockwise to release the thumb screw. 1-3.) Use the eject kit to remove controller board.
Hardware Operation Manual Installing the controller into Y3-12S6JS6 / Y3-12S6TS6 / Y3-12S6JS6-D / Y3-12S6AS6 Reverse the procedures as above to install the controller into Y3-12S6JS6 / Y3-12S6TS6 / Y3-12S6JS6-D / Y3-12S6AS6 H Hoott SSw waappppiinngg ttoo rreeppllaaccee tthhee FFaann M Moodduullee This section provides instructions for the removal and installation of the Fan Module indicated in the figure below.
Y3-12S6 Series Removing the Fan Module from JBOD system 1.) Turn anti-clockwise to release the thumb screw. 2.) Use the eject kit to remove Fan Module. 3.
Hardware Operation Manual Y3-12S6JS6-D Tower series Removing the Fan Module from Y3-12S6 Tower series: Installing the Fan module into Y3-12S6 Tower series: 1.) Turn anti-clockwise to release the thumb screw. 2.) Use the eject kit to remove Fan Module. 3.
Replacing Fan in a Fan Module: Step 1: Turn anti-clock wise to release the thumb screw. Step 2: slide the cover to blue arrow direction . Step 3: Remove the cover of Fan module and lift the Fans.
Hardware Operation Manual H Hoott SSw waappppiinngg ttoo rreeppllaaccee tthhee PPoow weerr M Moodduullee This section provides instructions for the removal and installation of the Power Module indicated in the figure below. Removing the Power Module from JBOD Removing the Power Module from system Y3-16 / 24S6 : JBOD system Y3-12S6 : Step1&2: Unscrew the thumb screw. Step3: Release the latch and hold it at unlock-position. Step4: Slide it back and lifting off. Step 1: Unscrew the thumb screw.
Hardware Operation Manual Removing the Power Module from RAID system Y3-12S6AS6 Series : Step1: Unscrew the thumb screw. Step 2: Slide it back and lifting off. Installing the Power module into JBOD system : Insert a Power module then fasten the screw.
Hardware Operation Manual Y3-12S6 Tower series Removing the Fan Module from Y3-12S6 Tower series: Installing the Fan module into Y3-12S6 Tower series: 1.) Turn anti-clockwise to release the thumb screw. 2.) Use the eject kit to remove Fan Module. 3.
Hardware Operation Manual IInnssttaallll tthhee Y Yoottttaa 33 JJB BO OD D SSyysstteem m iinn aa R Raacckk You are shipped with one rack mounting kit for each Yotta 3 JBOD system that you intend to rack mount. Yotta 3 JBOD system is designed for installation into an industry-standard 19-inch rack mount cabinet. Following the use of this section for installing the Yotta 3 JBOD system into a Rack Step1: Assemble and adjust the slide Rails a. Insert rear slide rail into left (right) slide rail b.
Hardware Operation Manual Step 2 : Install Clip nuts Attach M5 clip nut on each side of the front rack posts. Clip nuts use the figure 2 below to locate the clip nuts. Note: These clip nuts will be used to secure the subsystem through its front ears as will be discussed in Step 4.
Hardware Operation Manual Step 3 : Slide the subsystem into the server rack Lift the subsystem enclosure and slide it slowly and gently along the slide rail into the rack.
Hardware Operation Manual Step 4 : Secure the subsystem in the server rack Fasten two M5 screws through the chassis ears in the front side of the chassis. The JBOD system should now be securely mounted into the rack. Figure 4: Secure the subsystem in the server rack Install the JBOD system into the Rack Cabinet 1. Lift the JBOD system (one person on each side of the JBOD System) and approach the rack with the button-back of the JBOD system facing the end of Slide rails. 2.
Hardware Operation Manual H Hoow w ttoo ddeeppllooyy tthhee SSA ASS JJB BO OD Dw wiitthh Y Yoottttaa 33 SSA ASS R Raaiidd There are many topologies of SAS JBOD with Yotta 3 SAS Raid.
Hardware Operation Manual One SAS Raid subsystem with two SAS JBOD IN OUT OUT One SAS Raid subsystem with three SAS JBOD IN OUT OUT 47
Hardware Operation Manual One SAS Raid subsystem with four SAS JBOD IN OUT OUT 48
Hardware Operation Manual Dual Redundant Controller Unit (Rack-mount) One SAS Raid subsystem with one SAS JBOD JBOD Link A JBOD Link B Controller 1 24 Bay SAS-SAS RAID Subsystem (Rear Side) Controller 2 SAS Expander 1 24 Bay SAS JBOD SAS Expander 2 IN OUT OUT 49
Hardware Operation Manual One SAS Raid subsystem with two SAS JBOD 50
Hardware Operation Manual One SAS Raid subsystem with three SAS JBOD 51
Hardware Operation Manual One SAS Raid subsystem with four SAS JBOD 24 Bay SAS-SAS RAID Subsystem (Rear Side) JBOD Link A JBOD Link B Controller 1 Controller 2 IN 24 Bay SAS JBOD OUT SAS Expander 1 24 Bay SAS JBOD 24 Bay SAS JBOD SAS Expander 2 SAS Expander 1 16 Bay SAS JBOD 52 SAS Expander 2 OUT
Hardware Operation Manual Single Controller Unit (Tower): One SAS Raid subsystem with one SAS JBOD(Tower) 53
Hardware Operation Manual One SAS Raid subsystem with two SAS JBOD(Tower) OUT OUT IN 54
Hardware Operation Manual One SAS Raid subsystem with three SAS JBOD(Tower) OUT OUT IN 55
Hardware Operation Manual One SAS Raid subsystem with four SAS JBOD(Tower) OUT OUT IN 56
Hardware Operation Manual It supports up to four tiers and 122 SAS/SATAII peripheral devices (SAS/SATA HDDs + Raid Enclosures) by using SAS expanders. One Volume Set supports up to 32 HDDs One SAS Raid subsystem supports up to 128 Volumes One SAS Raid subsystem supports up to 122 SAS/SATAII peripheral devices (SAS/SATA HDDs + Raid Enclosures) by using SAS expanders. There are four tiers within JBOD topology as above: First tier is a RAID System.
Hardware Operation Manual RAID members need to be included at the same enclosure which means you need to create array in the same enclosure. If RAID members are created from two or more different enclosures, there would be some risks (for example: if a mini-SAS cable gets problem, more RAID members will be lost, volume sets belong to this Array may be failed.
Hardware Operation Manual Appendix A SSeettuupp C CL LII ccoonnnneeccttiioonn The SAS JBOD has a Command Line Interface (CLI) to manage all of its functions, including customization. Access the CLI via your PC’s terminal VT100 or ANSI emulation program, such as Microsoft HyperTerminal. With the SAS JBOD running and the RS-232 cable connected to the Terminal port on SAS JBOD 1. Open any UART communication tools like Hype Terminal • Bits per second: 115200 • Data bits: 8 • Parity: None • Stop bits: 1 2.
Hardware Operation Manual C CL LII C Coom mm maanndd SSeett The CLI has the following set of commands: HELP - Show All CLI commands and its usage Usage: help Example: CLI>help ============================================================ Test Command ============================================================ Set Password pass logout CLI shell lo Link rate Control link Index(D) High-Rate(D) Low-Rate(D) link Temperature Control th Index(D) High-Warn(D) Low-Warn(D) th System Information sys Alar
Hardware Operation Manual Drive Spin Up Control spin Delay(D)[ms] Num(D) spin Store System Setting st List Devices Status lsd [hdd | temp | volt | pwr | con | ..
Hardware Operation Manual Display expander SAS address sasaddr CLI Help help command ============================================================ Pass - Set Password Usage: pass (Max. 8 chars, Min.
Hardware Operation Manual Example: CLI>link Array Device Element (0x17): =================================================== NAME PHY NLR MAX MIN TYPE ADDRESS SLOT 01 7 6.0G 10 8 SAS 5000C500-103F7AA5 SLOT 02 6 6.0G 10 8 SAS 5000C500-10439631 SLOT 03 11 6.0G 10 8 SAS 5000C500-10438DFD SLOT 04 10 6.0G 10 8 SATA 5001B4D5-060E700A SLOT 05 3 6.0G 10 8 SATA 5001B4D5-060E7003 SLOT 06 4 6.0G 10 8 SATA 5001B4D5-060E7004 SLOT 07 12 6.
Hardware Operation Manual NAME ID CT('C) HTW LTW OTWarn ENC.
Hardware Operation Manual Vendor ID : Model ID : AXS-8016 Serial No. : 8888888888888888 Unit Serial No.
Hardware Operation Manual Firmware Family: 1 OemFamily: 0 Fast Boot: No Image Address: 0x14100000 HAL Revision: 0.7.0.0 SES Revision: 0.7.0.0 SCE Revision: 0.7.0.0 Enter “sys” in command line CLI>sys This command will show the status of Dual mode of the SAS Expander: Single SAS expander: When only 1 SAS Expander inserted Enter CLI>sys Dual Mode:Single Dual SAS Expander: When 2 SAS Expander inserted SAS Expander 1: enter CLI>sys Dual Mode: Redundant, I2C Master.
Hardware Operation Manual ======================================== NAME STATUS ALMSTATE Audible-Alarm Normal 0 Current Alarm Attribute: Warning Alarm: Sound2 Critical Alarm: Sound3 CLI> turn off buzzer CLI>bu mute Alarm beep Muted CLI> FAN - Operate the Fan Attribute Usage : fan Example: CLI>fan Cooling Element (0x03): ======================================== SPEED NAME CODE RPM STATUS Fan 01 3 3150 OK Fan 02 3 3270 OK Fan 03 3 3120 OK Fan 04 3 3300 OK 67
Hardware Operation Manual New FAN Speed Attribute: Type: Normal Lowest SpeedCode: 3 Warning SpeedCode: 7 Saved FAN Speed Attribute: Lowest SpeedCode: 3 Warning SpeedCode: 7 ST - Store System Setting Usage: st Example: CLI>st ALL Of The User Configurations are Saved.
Hardware Operation Manual ======================================== NAME PHY NLR MAX MIN TYPE ADDRESS SLOT 01 7 6.0G 10 8 SAS 5000C500-103F7AA5 SLOT 02 6 6.0G 10 8 SAS 5000C500-10439631 SLOT 03 11 6.0G 10 8 SAS 5000C500-10438DFD SLOT 04 10 6.0G 10 8 SATA 5001B4D5-060E700A SLOT 05 3 6.0G 10 8 SATA 5001B4D5-060E7003 SLOT 06 4 6.0G 10 8 SATA 5001B4D5-060E7004 SLOT 07 12 6.0G 10 8 SATA 5001B4D5-060E700C SLOT 08 14 6.
Hardware Operation Manual Connector02 19 02 Cooling Element (0x03): ======================================== SPEED NAME CODE RPM STATUS Fan 01 3 3120 OK Fan 02 3 3270 OK Fan 03 3 3150 OK Fan 04 3 3300 OK Temperature Element (0x04): ======================================== NAME ID CT('C) HTW LTW OTWarn ENC.
Hardware Operation Manual Slot14 Temp 16 NA 60 5 No Slot15 Temp 17 NA 60 5 No Slot16 Temp 18 NA 60 5 No Voltage Element (0x12): ======================================== NAME VOLT(V) OVLMT UVLMT STATUS 1V 0.97 1.07 0.94 None 5V 5.04 5.32 4.63 None 3.3V 3.21 3.53 3.05 None 12V 11.92 12.80 11.
Hardware Operation Manual CLEARLOGS - Print System Log.
Hardware Operation Manual Appendix B SSA ASS JJB BO OD D ffiirrm mw waarree uuppddaattee pprroocceedduurree The procedure to update firmware thru UART: 1.) Commands to update firmware, step as follow, 2.) First type "fdl boot 0" under "CLI>" prompt, 3.) Then under hyper terminal click “file” at top to pull down the menu. Choose "Xmodem (Checksum)" and select the firmware file in the directory then press send. If file is receiving within the timeout limit (60sec), then firmware update will proceed.
Hardware Operation Manual The firmware date are presented in the following filename format, a.) Boot & FW files(boot & code):sas2xfwXXXX.fw b.) Data file(mfgb): mfgdat6gYYYY.rom 5.) Firmware update can be cancel by pressing Q or q. 6.) After updating boot file, repeat steps 1-5 to update the Firmware File but with different command. CLI> fdl code 0 Then use file "sas2xfwXXXX.fw” to update the FW file.
Hardware Operation Manual 7.) After updating firmware, repeat steps 1-5 to update the Data File but with different command. CLI> fdl mfgb 0 Then use file "mfgdata.rom” to update the Data file. 8.) After updated both files, perform a Power Cycle on the SAS JBOD. Before upgrade SAS Expander Firmware, all I/O access must be stopped on the SAS JBOD Before Performing Power Cycle on the SAS JBOD, Server and RAID System need to be Power off. Upgrade Dual SAS Expander : 1.
Hardware Operation Manual Appendix C S p e c if ic a t i o n s Y3-24S6JS6/Y3-16S6JS6/Y3-12S6JS6 Model Y3-24S6JS6 SAS Y3-16S6JS6 SAS Rack mountable x1 System Type SAS Expander Host Interface Host Transfer Rate Disk Interface Disk Channel Hot Swap and redundant Hot Spare Enclosure Monitoring (SES) Remote Terminal Configuration Operating Systems Y3-12S6JS6 SAS One 4 x 6Gb/s SAS Ports, Standard Mini SAS connectors 4 x 6Gb/ Sec per port SAS 6Gb / SATA 6Gb 16 Bay Disk Channels 24 Bay Disk Channels 12 Ba
Hardware Operation Manual Y3-24S6TS6/Y3-16S6TS6/Y3-12S6TS6 Model Y3-24S6TS6 SAS Y3-16S6TS6 SAS Rack mountable x2 System Type SAS Expander Host Interface Host Transfer Rate Disk Interface Disk Channel Hot Swap and redundant Hot Spare Enclosure Monitoring (SES) Remote Terminal Configuration Operating Systems Y3-12S6TS6 SAS One 4 x 6Gb/s SAS Ports, Standard Mini SAS connectors /per controller 4 x 6Gb/ Sec per port 24 Bay Disk Channels SAS & NL SAS 6Gb 16 Bay Disk Channels 12 Bay Disk Channels Yes (SA
Hardware Operation Manual Y3-12S6JS6-D Model System Type SAS Expander Host Interface Host Transfer Rate Disk Interface Disk Channel Hot Swap and redundant Hot Spare Enclosure Monitoring (SES) Remote Terminal Configuration Operating Systems Y3-12S6JS6-D SAS Tower x1 One 4 x 6Gb/s SAS Ports, Standard Mini SAS connectors 4 x 6Gb/ Sec per port SAS 6Gb / SATA 6Gb 12 Bay Disk Channels Yes (Power Supply, Drive and Fan). Yes (Drive). In Band SES via SAS Yes.
Hardware Operation Manual Y3-12S6AS6 Y3-12S6AS6 SAS Rack mountable x1 Model System Type SAS Expander Host Interface Host Transfer Rate Disk Interface Disk Channel Hot Swap and redundant Hot Spare Enclosure Monitoring (SES) Remote Terminal Configuration Operating Systems One 4 x 6Gb/s SAS Ports, Standard Mini SAS connectors 4 x 6Gb/ Sec per port SAS 6Gb / SATA 6Gb 12 Bay Disk Channels Yes (Power Supply, Drive and Fan). Yes (Drive). In Band SES via SAS Yes.