Installation guide

Chapter 4. Web Browser-Based Configuration
53
4.5.5 Rename RAID Set
The default RAID set name will always appear as “Raid Set #” when it is first created
by the controller. The "Rename Raid Set" function is for customer to rename the
default RAID set name.
To rename a RAID set from a group of RAID sets:
(1). Click on the ”Rename Raid Set" link.
(2). Click the RAID set check box from the list that you wish to rename. Click the
“Submit” button. The following screen appears. Use this option to rename the RAID
set name.
4.5.6 Activate Incomplete Raid Set
If one of the disk drives is removed in power off state, the RAID set state will change
to “Incomplete State”. If the user wants to continue to operate the controller without
power-off the RAID subsystem, the user can use the “Activate Incomplete Raid Set”
option to active the RAID set. After the user completes this function, the Raid State
will change to “Degraded Mode” and start to work.
To activate the incomplete the RAID set, click on the “Activate Raid Set” link. A “Select
the RAID Set to Activate” screen is displayed showing all RAID sets existing on the
current controller. Click the RAID set number to activate in the select column. Click on
the Submit” button on the screen to activate the RAID set that had a disk removed (or
failed) in the power off state. The RAID subsystem will continue to work in degraded
mode.