Installation guide
Software Operation Manual
56
Item Warning Condition
Controller Board Temperature
> 70 Celsius
Backplane Temperature
> 55 Celsius
Controller Fan Speed
< 1700 RPM
Power Supply +12V
< 10.5V or > 13.5V
Power Supply +5V
< 4.7V or > 5.3V
Power Supply +3.3V
< 3.0V or > 3.6V
CPU Core Voltage +1.5V
< 1.35V or > 1.65V
3.7.11 Show System Information
Choose this option to display Main processor, CPU instruction cache size, CPU
data cache size, system memory, firmware version, BOOT ROM version, MTP
firmware, serial number, unit serial, controller name, current IP, target SAS chip,
devices chip, SAS expander, host port link and JBOD port link. To check the
system information, press ENT to enter the main menu. Press UP/DOWN
button to select the “Show System Information” option, and then press ENT. All
major controller system information will be displayed. Press UP/DOWN buttons
to browse all the system information.