Installation guide

Chapter 3. LCD Panel Configuration
53
the other 123.4 GB. “Multiples Of 1G” truncates the fractional part. This makes
the same capacity for both of these drives so that one could replace the other.
Disabled: It does not truncate the capacity.
3.7.5.11 Shutdown The Controller
To shutdown the RAID controller, press UP/DOWN buttons to select “Shutdown
The Controllerand then press ENT to accept the selection. The confirmation
screen will be displayed and then press ENT to accept the function.
3.7.5.12 Restart Controller
To restart the RAID controller, press UP/DOWN buttons to select “Restart
Controller” and then press ENT to accept the selection. The confirmation screen
will be displayed and then press ENT to accept the function.
Note
It can only work properly at Host and Drive without any activity.
3.7.6 Fiber Channel Config
Use to configure the Fiber channel function. Press the UP/ DOWN to select
Fiber Channel Config and then press the ENT to accept the selection. Press
UP/ DOWN to select Channel and then press the ENT to accept the selection.
3.7.6.1 Fiber Speed
Press the UP/ DOWN to select Ch0~3 Speed and then press the ENT to accept
the selection. Press UP/ DOWN to select speed (Auto, 2Gbps, 4Gbps, and
8Gbps) then press ENT to accept the selection. The confirmation screen will be
displayed and then press ENT to accept the change.
3.7.6.2 Fiber topology
Press the UP/ DOWN to select Ch0~3 Topology and then press the ENT to
accept the selection. Press UP/ DOWN to select speed (Auto, Loop,
Point-Point, Fabric and Loop/MNID) then press ENT to accept the selection.
The confirmation screen will be displayed and then press ENT to accept the
change.
3.7.6.3 Hard Loop
This setting is effective only under the setting is “Loop topology”. When enabled,
you can manually set the Loop ID in the range from 0 to 125. Press the UP/