Installation guide

Software Operation Manual
204
check Power Supply
Power Failed
Urgent Power # failure Replace Power #
Fan Failed
Urgent
Cooling Fan # failure or speed
below 1700RPM
Replace Fan #
UPS AC Power
Loss
Urgent
UPS AC Power failure
detected
Check AC power status or
cabling between UPS and
RAID system.
Controller Temp.
Recovered
Serious
Controller temperature back to
normal level
Backplane Tempe.
Recovered
Serious
Backplane temperature back to
normal level
HDD Temp.
Recovered
#.#V Recovered
Serious Voltage output back to normal
Power #
Recovered
Serious
Power # back to on-line state
Fan # Recovered
Serious
Fan # back to on-line state
UPS AC Power
Recovered
Serious
UPS AC power back to on-line
state.
Raid Powered On
Warning Raid Power On
Test Event
Urgent Test Event
Power On With
Battery Backup
Warning
Raid Power On with battery
backup
Incomplete RAID
Discovered
Serious
Some Raid Set member disks
missing before power on
Check disk information to
find out which channel
missing.
HTTP Log In
Serious
a HTTP login detected
Telnet Log In
Serious
a Telnet login detected
VT100 Log In
Serious
a VT100 login detected
API Log In
Serious
a API login detected
Lost Rebuilding/
Migration LBA
Urgent
Some rebuilding / migration
RAID set member disks
missing before power on
Reinserted the missing
member disk back,
controller will continued the
Incomplete