Technical Guide
556454-YTG-D-0414
Johnson Controls Unitary Products 5
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
TCHD30S41S3
MX16CN21 21.0 FC/MC35C 1000 28.6 21.4 15.00 13.05
MX16CN21 21.0 FC/MC43C 950 28.8 21.4 15.75 13.60
MX16CN21 21.0 FC/MC48C 950 29.0 21.6 15.85 13.75
MX20DN21 24.5 FC/MC48D 1000 29.0 21.8 14.50 12.75
TCHD36S41S3
AHE36C 21.0 – 1190 34.4 25.4 14.75 12.75
AHE42D 24.5 – 1180 35.0 25.8 15.50 13.25
AHR36B 17.5 – 1245 33.8 24.6 13.25 11.50
AHR42C 21.0 – 1230 34.6 25.6 13.75 12.00
AHV36C 21.0 – 1215 34.4 25.6 14.50 12.00
AHV42D 24.5 – 1180 35.0 25.8 15.00 12.75
AHV48D 24.5 – 1155 34.4 25.2 15.00 12.50
MV12B 17.5 FC/MC43B 1200 34.4 25.2 14.50 12.50
MV12D 24.5 FC/MC48D 1150 34.6 25.2 15.00 13.00
MV16C 21.0 FC/MC43C 1200 34.6 25.4 15.00 13.00
MV16C 21.0 FC/MC48C 1200 35.0 25.6 15.25 13.10
MX12BN21 17.5 FC/MC35B 1125 33.4 24.1 14.00 11.75
MX12BN21 17.5 FC/MC43B 1125 33.8 24.5 14.50 12.35
MX12DN21 24.5 FC/MC48D 1125 34.2 25.1 15.25 13.00
MX16CN21 21.0 FC/MC35C 1200 33.6 24.7 13.75 11.75
MX16CN21 21.0 FC/MC43C 1200 34.2 25.3 14.60 12.50
MX16CN21 21.0 FC/MC48C 1200 34.4 25.7 14.65 12.50
MX20DN21 24.5 FC/MC48D 1200 34.8 25.9 15.25 12.75
TCHD48S41S3
AHE48D 24.5 – 1600 47.0 34.0 14.00 12.00
AHE60D 24.5 – 1565 48.0 34.4 14.25 12.25
AHR48D 24.5 – 1610 47.0 34.0 13.00 11.50
AHR60D 24.5 – 1620 47.5 34.4 13.25 11.50
AHV48D 24.5 – 1585 46.5 33.2 13.50 11.50
AHV60D 24.5 – 1570 47.0 34.0 13.75 11.75
MV16C 21.0 FC/MC48C 1600 47.5 34.2 14.00 12.10
MV16C 21.0 FC60C 1625 47.0 33.6 13.75 11.75
MV20D 24.5 FC/MC48D 1600 47.5 34.2 14.00 12.00
MV20D 24.5 FC/MC60D 1600 45.5 33.0 13.50 11.60
MV20D 24.5 FC/MC62D 1600 48.0 34.6 14.25 12.25
MV20D 24.5 FC64D 1630 49.5 36.0 14.50 12.50
MX16CN21 21.0 FC/MC48C 1600 46.5 33.5 13.80 11.90
MX16CN21 21.0 FC60C 1600 46.5 33.3 13.85 11.95
MX20DN21 24.5 FC/MC48D 1525 46.5 33.1 14.25 12.25
MX20DN21 24.5 FC/MC60D 1525 47.0 33.5 14.50 12.25
MX20DN21 24.5 FC/MC62D 1525 47.0 33.7 14.40 12.45
MX20DN21 24.5 FC64D 1525 48.5 34.7 14.85 12.80
TCHD60S41S3
AHE60D 24.5 – 1835 57.5 40.5 13.50 11.50
AHV60D 24.5 – 1635 56.5 38.3 13.25 11.00
MV20D 24.5 FC/MC62D 1800 57.5 39.5 13.40 11.30
MV20D 24.5 FC64D 1855 59.0 41.5 13.50 11.50
MX20DN21 24.5 FC/MC62D 1750 57.0 39.2 13.75 11.60
MX20DN21 24.5 FC64D 1750 58.0 40.6 14.00 11.75
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
13 SEER AC WITH AIR HANDLERS