Technical Guide

556454-YTG-D-0414
Johnson Controls Unitary Products 5
— = Not applicable.
MA Modular Air Handlers use Coil Only Ratings.
TCHD30S41S3
MX16CN21 21.0 FC/MC35C 1000 28.6 21.4 15.00 13.05
MX16CN21 21.0 FC/MC43C 950 28.8 21.4 15.75 13.60
MX16CN21 21.0 FC/MC48C 950 29.0 21.6 15.85 13.75
MX20DN21 24.5 FC/MC48D 1000 29.0 21.8 14.50 12.75
TCHD36S41S3
AHE36C 21.0 1190 34.4 25.4 14.75 12.75
AHE42D 24.5 1180 35.0 25.8 15.50 13.25
AHR36B 17.5 1245 33.8 24.6 13.25 11.50
AHR42C 21.0 1230 34.6 25.6 13.75 12.00
AHV36C 21.0 1215 34.4 25.6 14.50 12.00
AHV42D 24.5 1180 35.0 25.8 15.00 12.75
AHV48D 24.5 1155 34.4 25.2 15.00 12.50
MV12B 17.5 FC/MC43B 1200 34.4 25.2 14.50 12.50
MV12D 24.5 FC/MC48D 1150 34.6 25.2 15.00 13.00
MV16C 21.0 FC/MC43C 1200 34.6 25.4 15.00 13.00
MV16C 21.0 FC/MC48C 1200 35.0 25.6 15.25 13.10
MX12BN21 17.5 FC/MC35B 1125 33.4 24.1 14.00 11.75
MX12BN21 17.5 FC/MC43B 1125 33.8 24.5 14.50 12.35
MX12DN21 24.5 FC/MC48D 1125 34.2 25.1 15.25 13.00
MX16CN21 21.0 FC/MC35C 1200 33.6 24.7 13.75 11.75
MX16CN21 21.0 FC/MC43C 1200 34.2 25.3 14.60 12.50
MX16CN21 21.0 FC/MC48C 1200 34.4 25.7 14.65 12.50
MX20DN21 24.5 FC/MC48D 1200 34.8 25.9 15.25 12.75
TCHD48S41S3
AHE48D 24.5 1600 47.0 34.0 14.00 12.00
AHE60D 24.5 1565 48.0 34.4 14.25 12.25
AHR48D 24.5 1610 47.0 34.0 13.00 11.50
AHR60D 24.5 1620 47.5 34.4 13.25 11.50
AHV48D 24.5 1585 46.5 33.2 13.50 11.50
AHV60D 24.5 1570 47.0 34.0 13.75 11.75
MV16C 21.0 FC/MC48C 1600 47.5 34.2 14.00 12.10
MV16C 21.0 FC60C 1625 47.0 33.6 13.75 11.75
MV20D 24.5 FC/MC48D 1600 47.5 34.2 14.00 12.00
MV20D 24.5 FC/MC60D 1600 45.5 33.0 13.50 11.60
MV20D 24.5 FC/MC62D 1600 48.0 34.6 14.25 12.25
MV20D 24.5 FC64D 1630 49.5 36.0 14.50 12.50
MX16CN21 21.0 FC/MC48C 1600 46.5 33.5 13.80 11.90
MX16CN21 21.0 FC60C 1600 46.5 33.3 13.85 11.95
MX20DN21 24.5 FC/MC48D 1525 46.5 33.1 14.25 12.25
MX20DN21 24.5 FC/MC60D 1525 47.0 33.5 14.50 12.25
MX20DN21 24.5 FC/MC62D 1525 47.0 33.7 14.40 12.45
MX20DN21 24.5 FC64D 1525 48.5 34.7 14.85 12.80
TCHD60S41S3
AHE60D 24.5 1835 57.5 40.5 13.50 11.50
AHV60D 24.5 1635 56.5 38.3 13.25 11.00
MV20D 24.5 FC/MC62D 1800 57.5 39.5 13.40 11.30
MV20D 24.5 FC64D 1855 59.0 41.5 13.50 11.50
MX20DN21 24.5 FC/MC62D 1750 57.0 39.2 13.75 11.60
MX20DN21 24.5 FC64D 1750 58.0 40.6 14.00 11.75
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ANSI/AHRI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH (Relative Humidity), and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTUs at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTUs during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.
1. MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.
COOLING CAPACITY - With Air Handler Coils (Continued)
UNIT
MODEL
AIR HANDLER
COIL
MODEL
1
COOLING
MODEL WIDTH
RATED
CFM
NET MBH
SEER EER
TOTAL SENS.
13 SEER AC WITH AIR HANDLERS