Specifications

GENERAL
YORK Model DCE units are single package air conditioners
designed for outdoor installation on a rooftop or a slab. These
units can be equipped with field installed electric heaters for
cooling/heating applications.
The units are completely assembled on rigid, permanently
attached base rails. All piping, refrigerant charge, and electrical
wiring is factory installed and tested. The units require only
electric power and duct connections at the point of installation.
The electric heaters have nickel-chrome elements and utilize
single point power connection.
INSPECTION
As soon as a unit is received, it should be inspected for possible
damage during transit. If damage is evident, the extent of the
damage should be noted on the carrier’s freight bill. A separate
request for inspection by the carrier’s agent should be made in
writing. Refer to Form 50.15-NM for additional information.
REFERENCE
Additional information on the design, installation, operation and
service of this equipment is available in the following reference
forms:
55.70-N1 - General Installation
55.70-N2 - Pre-start & Post-start Check List
530.18-N9.1V - Electric Heater Accessory
530.18-N3.2V - Economizer Accessory
530.18-N3.4V - Motorized Outdoor Air Damper Accy.
530.18-N3.5V - Fuse Block Accessory
690.15-N25V - Low Ambient Accessory
Renewal Parts:
Refer to the Renewal Parts Manual for complete listing of
replacement parts on this equipment.
All forms referenced in this instruction may be ordered from:
Publications Distribution Center
Unitary Products Group
P.O. Box 1592, York, Pa. 17405
APPROVALS
Design certified by U.L. & CGA as follows:
1. For use as a cooling only unit or a cooling unit with
supplemental electric heat.
2. For outdoor installation only.
3. For installation on combustible material.
®
SUNLINE 2000
ELECTRIC / ELECTRIC
SINGLE PACKAGE AIR CONDITIONERS
INSTALLATION INSTRUCTION
Supersedes: 530.18-N9Y (693)
530.18-N9Y (995)
Installer should pay particular attention to the words:
NOTE, CAUTION
and
WARNING
. Notes are intended to clarify or
make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that per-
sonal injury and/or equipment damage may result if installation procedure is not handled properly.
MODELS D3CE090, 102, 120 (STYLE B) &
D4CE150 (STYLE A)
(8.5-9.0 EER)
035-13091
CAUTION
THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE
LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED
TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.
THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH
WARNING
OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY
OR PROPERTY DAMAGE.
INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE
208/230/575 VOLT
MODELS ONLY
208/230/460 VOLT
MODELS ONLY