MODEL NUMBER
OUTDOOR INDOOR OUTDOOR INDOOR
DHPM09CSM41Q1 DHPM09NWM41Q1 DHPM12CSM41Q1 DHPM12NWM41Q1
Nominal Cooling BTU/h 9000 11800
Min.~Max. Cooling BTU/h 4435~10600 4500~14000
Nominal Heating BTU/h 9300 13100
Min.~Max. Heating BTU/h 3200~11100 3250~14500
HSPF 9.8 9.6
SEER 22 20
EER 13.64/13.64 11.94/10.92
Clg. Operating Range °F(°C) 41°F~115°F(5ºC~46ºC) 41°F~115°F(5ºC~46ºC)
Htg. Operating Range °F(°C) 5°F~86°F(-15ºC~30ºC) 5°F~86°F(-15ºC~30ºC)
Moisture Removal (l/h) 0.8 1.4
Moisture Removal Pt./h 1.7 3
Voltage/Frequency/Phase 115/60/1 115/60/1
Recommended Fuse Size (A) 3.15A 3.15A
Indoor Air Circ. C.F.M. (m3/h) Turbo 951(560) 866(510)
Indoor Air Circ. C.F.M. (m3/h) Hi 849(500) 798(470)
Indoor Air Circ. C.F.M. (m3/h) Medium 730(430) 730(430)
Indoor Air Circ. C.F.M. (m3/h) Low 628(370) 628(370)
Indoor Sound Pressure Level dB (A) Turbo 38 40
Indoor Sound Pressure Level dB (A) Hi 34 36
Indoor Sound Pressure Level dB (A) Medium 30 32
Indoor Sound Pressure Level dB (A) Low 26 26
Outdoor Fan Speed RPM Clg/Htg 900 900
Fuse (A) 25A / 25A /
Outdoor Noise Sound Pressure Level dB (A) (Clg/Htg) 50 53
Current Rated (A): Cooling 7 11
Heating 7.5 12.5
Power Use Rated (kw): Cooling 0.66 1
Heating 0.7 1.2
Indoor Fan Speeds Stage 4 4
Air Direction: Horizontal Manual Manual
Air Direction: Vertical Automatic Automatic
Air Filter Washable Washable
Connection Method Flare Flare
Combined Max. Lgth Ft 50 50
Max. Vertical Diff. Ft 33 33
Conn. Pipe Diameter Inch Suc. 3/8 Dis. 1/4 Suc. 3/8 Dis. 1/4
Unit Height Inch 21 11 21 11
Unit Height mm 533 279 533 279
Unit Width Inch 33.4 33 33.4 33
Unit Width mm 848 838 848 838
Unit Depth Inch 12.6 7 12.6 7
Unit Depth mm 320 178 320 178
Refrigerant type R410A R410A
Refrigerant Charge (ozs) 42 45.5
Carton Height in inches 22.8 14 22.8 14
Carton Width in inches 36 34.5 36 34.5
Carton Depth in inches 14.2 10 14.2 10
Unit Weight (lbs) 91 31 97 31
Shipping Weight (lbs) 110 38 118 38