Technical Guide
505428-YTG-R-1114
Johnson Controls Unitary Products 5
Refer to the unit installation instructions for other application 
possibilities.
Benefits
Air handling units are designed with two distinct modules to 
provide maximum application flexibility. All are shipped as 
single packages with the blower module mounted on top of 
the coil module. The blower module can be repositioned in 
the field to meet a large number of vertical and horizontal 
applications.
The 7.5 thru 20 Ton blower module includes the blower 
wheels along with factory-mounted motor and drive. The 25 
Ton blower module includes the blower wheels with field 
mounted motor and drives. All models offer two motor 
horsepower options to meet both standard and high static 
airflow requirements.
The coil module includes direct expansion coils, 2 in. 
throwaway filters with the option to accept 4” filters, liquid line 
solenoid valves for capacity reduction, thermal expansion 
valves, distributors and a non-corrosive, composite 
condensate drain pan. 
Every air handling coil is pressurized with air and leak tested 
under water. After the headers are brazed onto the coil and 
the coil is installed in the unit, the coil is pressurized with 
nitrogen for pressure testing and additional leak testing. After 
the coil is evacuated and dehydrated, it is pressurized with a 
holding charge of nitrogen for storage and/or shipping.
These air handlers, combined with condensing units, provide 
years of quiet, efficient and dependable operation. These 
units are manufactured under ISO 9001 Quality System 
Certification.
Unit Installation
Units may be bottom-supported or ceiling-suspended and 
can be arranged to meet almost any space or duct 
requirements. Each unit is available with a choice of blower 
motors horsepower and other accessories to make them 
suitable for most applications.
Air Handling units are available in either two or four pipe 
configurations from 7.5 to 25 tons. The dual and single circuit 
options provide a wide variety of application and unit match-
up possibilities.
Blower Motors:
 Different HP motors are available for each 
unit to meet almost any air delivery requirement. All motors 
are UL approved, have permanently lubricated ball bearings 
and are mounted within the insulated cabinet of the units to 
minimize the transmission of sound to the surrounding space. 
1.5-5 HP motors are inherently protected. 7.5 HP motors 
require motor overload protection.
Overload Relay (7.5HP):
 These blower motors do not have 
inherent protection and require external motor overload 
protection. NC/ND240 "F" models Overload Relays are 
factory installed. NC300 models Overload Relays are field 
installed. Power wiring for blower motor is supplied in the 
Overload Relay Kit. See details in Overload Relay Kit and 
Overload Relay Setting Tables on Page 70.
Factory-Mounted Components
Part Load Operation:
 These air handlers with DX (Direct 
Expansion) coils rated at 10 tons of capacity and above have 
multiple coils with pre-piped distributors, expansion valves 
and solenoid valves. Field modifications are not required for 
part load operations. Capacity reduction not only provides 
economical operation, but also maintains stable temperature 
and humidity levels in the conditioned space.
BAS Control:
 Simplicity® SE with Communication Option 
Control - The York® Simplicity® SE with Communication 
Option Control is factory installed. It includes all the features 
of the Simplicity® SE control with an additional gateway to 
BACnet MS/TP (programmable to Modbus or N2 protocols).
Easy Service: Serviceable expansion valves are provided on 
every unit. These valves are factory-installed to provide many 
years of trouble-free operation. If service is required, it is not 
necessary to unbraze any joints. The expansion valves also 
include a tee fitting to allow easy installation of hot gas 
bypass if required.
Coil Protection: The indoor coils of these air handlers can 
have factory applied Technicoat or Electrofin coating to 
provide extended life to the indoor coil in standard 
applications and additional corrosion protection on those 
applications in sea coast or corrosive environments.
Accessories
Base Sections:
 Base sections can be used to elevate units 
above the floor. If desired, a moderate percentage of outdoor 
air may be introduced through these sections by cutting an 
access opening to accommodate the outdoor air duct 
connection. These bases include a durable finish to match 
the evaporator blower unit. The base may have to be 
insulated for certain applications.
Hot Water Coils:
 Drain-able water coils are available for field 
installation between the blower and the coil modules of both 
horizontal and vertical units. Since their casings match the 
dimensions and the finish of the basic units, they become an 
integral part of the unit after installation. The coils slide out of 
their casings for easy installation. Hot water coils have 
copper tubes that have been mechanically expanded into 
aluminum fins. Both headers are located on the same end of 
the coil. Coils are leak-tested at 325 psig under water and 
dried before their connections are capped for storage and 
shipping.
Steam Coils:
 Steam coils are available for installation 
between the blower and coil modules of both horizontal and 
vertical units. Since the casing matches the dimensions and 
the finish of the basic unit, it becomes an integral part of the 
unit after installation. The coil slides out of the casings for 
easy installation and is pitched in the casings to facilitate 
condensate drainage. The coil has copper tubes that have 
been mechanically expanded into aluminum fins. Both 
headers are located on the same end of the coil. The coil is 
leak-tested at 325 psig and dried before the connections are 
capped for storage and shipping.
Bottom Return:
 Air handling unit can be quickly converted to 
bottom return for both vertical and horizontal applications. All 
that is required is the removal of several screws and a single 