Technical Guide

TECHNICAL GUIDE
MODELS: MX
MODULAR STANDARD ECM AIR HANDLERS
FOR USE WITH SPLIT SYSTEM
COOLING & HEAT PUMP
1200 - 2000 CFM BLOWERS
3 - 5 TON COILS
OPTIONAL 1 & 3
ELECTRIC HEATERS
Due to continuous product improvement,
specifications are subject to change without notice.
Visit us on the web at:
www.york.com
Additional rating information can be found at:
www.ahridirectory.org
ISO 9001
Certified Quality
Management System
635425-YTG-D-0413
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
This unique modular system allows the flexibility to handle any
application. These versatile coils and blowers may be used for
upflow, downflow, or horizontal left or right applications. They
may be combined to function as a cooling only unit or with a
heat pump including electric heat for 1 and 3 phase applica-
tions. The blower and electric heater could be used as stand
alone electric furnaces.
FEATURES
Blowers - Models to match any air flow or voltage requirement.
The compact size allows easy installation. Blowers are sized to
deliver design air quantity both efficiently and quietly. All models
use a high efficiency brushless DC motor to provide cooling
SEER rating enhancement. The durable, pre-painted steel pro-
tects the unit against rust and corrosion. All models have 1 inch
foil face fiber glass insulation, providing a thermal insulation
value of R-4.2.
Coils - Staggered rows of rifled copper tubes are mechanically
expanded into enhanced surface aluminum fins to provide high
heat transfer and long-lasting quality. The MC multi-position
coils may be used for upflow, downflow, and horizontal left or
right applications. Coil cabinets are insulated with 3/4" foil face
insulation to prevent sweating.
Thermal Expansion Valves - Coils are ordered as "Flex-coil"
units without a factory installed metering device or with R-410A
factory installed TXV’s. Flex-coil models allow for field installed
R-22 or R-410A TXV’s for added flexibility to meet refrigerant
system choice.
Electric Heaters - Both single and three phase electric heater
models are available to match any requirement. All heaters
include nickel-chromium elements with a 5-year limited war-
ranty on single phase heating elements and 1 year limited war-
ranty on 3 phase heating elements. Sequential operation is
provided to control heaters in all models. Circuit breakers are
used in 208/230 volt, single-phase heaters of 15 KW and larger.
Models equipped with circuit breakers may be altered in the
field to use multi-source power supply. Over-temperature limit
switches provide protection from airflow loss with fusible link
backup protection.
Accessories - A full line of matching accessories available for
use with the blower and coils to allow any type application.
LIMITATIONS
These units must be wired and installed in accordance with all
national and local safety codes.
Voltage limits are as follows:
AIR HANDLER VOLTAGE
NORMAL OPERATING
VOLTAGE RANGE*
208/230-1-60 187 - 253
* Rated in accordance with ARI Standard 110, utilization range “A”.
Air flow must be within the minimum and maximum limits approved for electric
heat, evaporator coils and outdoor units.

Summary of content (12 pages)