Performance Parameters
23
Ⅷ
Performance Parameters
Rated Working Conditions of the Air Conditioning Unit
Table 18 Working Temperature Range
Indoor side state Outdoor side stae
Dry bulb temp.
℃
Wet bulb temp.
℃
Dry bulb temp.
℃
Wet bulb temp.
℃
Rated Cooling 27 19 35 24
Max. cooling 32 23 48 26
Min. cooling 21 15 18 —
Rated Heating 20 15 7 6
Max. heating 27 — 24 18
Min. heating 20 15
-
15
-
16
Notes
:
① .
The heating/cooling capacity and noise listed below are all measured before the shipment.
② .
All parameters listed below are measured under the standard working conditions. If there is any
change, the parameters marked on the nameplate always prevail.
③ .
The heating capacity of the indoor unit just involves that of the heat pump but apart from that of the
auxiliary electric heater.