EOKC 09, 12, 18, 24 R by johnson controls Ref: GB Floor/Ceiling Multisplit Inverter Installation Instructions Johnson Controls Manufacturing España, S.L. is participating in the EUROVENT Certification Programme. Products are as listed in the EUROVENT Directory of Certified Products, in the program AC1, AC2, AC3, LCP and FC.
User Notice When operating, the entire capacity of the cooperating indoor unit should be not larger than 150% of outdoor unit. Otherwise, it will cause the shortage of cooling (heating) capacity. The power supply of the entire unit must be the power supply of outdoor unit. And disconnect the main power of outdoor units before cleaning. In order to turn on the units successfully, the main power switch should be opened 8 hours before the operation.
by johnson controls Contents Safety Information .............................................................................................. 4 Selection of Installation Location and Precautions............................................. 5 1 Selection of Installation Location for Air Conditioner Unit ......................................... 5 2 Selection of Installation Location .................................................................................
by johnson controls Safety Information Ⅰ Safety Information Please read this manual carefully before use this unit, and operate it correctly according to the guide in this manual. Please take specially note to the meaning of these two marks: Warning! This mark means that it may cause casualty or badly hurt if the operation is incorrect. Caution! This mark means that it may cause casualty or property loss if the operation is incorrect.
by johnson controls Selection of Installation Location and Precautions Ⅱ Selection of Installation Location and Precautions 1 Selection of Installation Location for Air Conditioner Unit The installation of air conditioner unit must be in accordance with national and local safety codes. Installation quality will directly affect the normal use of air conditioner unit. The user is prohibited from installation by himself. Please contact your dealer after buying this machine.
by johnson controls Installation of Floor And Ceiling Type Indoor Unit Installation of Floor And Ceiling Type Indoor Unit 1 Space dimension for installation of the unit The space around the unit is adequate for ventilation. (Refer to Fig.1) Fig.1 2 Important notice a. The unit must be installed by the professional personnel according to this install instruction to ensure the well use. Please contact the local YORK special nominated repair department before installation.
by johnson controls Installation of Floor And Ceiling Type Indoor Unit * Loosen two hanger bracket setting bolts (M8) on eath side for less than 10mm. Remove two hanger bracket fixing bolts (M6) on the rear side. Detach the hanger bracker by pulling it backward (Refer to Fig.5). Fig.2 c. Set the suspension bolt. (Use W3/8 or M10 size suspension bolts) Fig.3 * Adjust the distance from the unit to the ceiling slab beforehand. (Refer to Fig.4) d. Fix the hanger bracket to the suspension bolt.
by johnson controls Installation of Floor And Ceiling Type Indoor Unit Celling Hanger bracket 40 or less Hanger bracket setting bolt(M8) Suspension bolt Hanger bracket Hanger bracket fixing bolt(M6) Fig.4 Fig.5 Celling slab BOLT POSITION INWARD Hanger bracket Fig.7 Fig.6 Fig.8 Fig.9 When installing the indoor unit, you can refer the paper pattern for installation, and make sure that the drainage side must be 10mm lower than the other side in order t .
by johnson controls Installation of Floor And Ceiling Type Indoor Unit 4 Electrical wiring Caution: The power of every indoor unit should be connected in outdoor unit. a. Open surface panel. b. Remove the electrical box cover. c. Route the power connection cord from the back of the indoor unit and pull it toward the front through the wiring hole upward. d.
by johnson controls Installation of Floor And Ceiling Type Indoor Unit ERJC(36)R INDOOR UNIT A XT5X POWER INDOOR UNIT C INDOOR UNIT B T4 INDOOR UNIT D XT3X N L T2 XT1 OUTDOOR UNIT Caution ! ① . The incorrect of wiring connecting would lead malfunction of some of the electric elements. ② . Make sure that the lead between the connect end and the clamp end has some need space after the ③ . The appliance shall be installed in accordance with national wiring regulations.
by johnson controls Installation of Floor And Ceiling Type Indoor Unit 11 Large seeing pad⑤ (Accessory) Cramp⑤ (Accessory) Air outlet Watering can 4m m or le ss Fig.12 Fig.13 Fig.14 6 Install the connection pipes Connect the connect pipe with the two relative leading pipe, tie the nut on tie–in of the connect pipe tightly. Caution ! * Be careful in bending the connection pipes, or you will damage the pipes. * If the tightening torque is too great in tightening the flare nut, leakage will happen.
by johnson controls Constitutes and Names of Every Part of Floor And Ceiling Type Indoor Unit Constitutes and Names of Every Part of Floor And Ceiling Type Indoor Unit Air outlet Guide louver Surface Panel Air filter, purifier (in air inlet grille) Air inlet Connecting pipe Suitable model: EOKC(09)R EOKC(12)R EOKC(18)R EOKC(24)R Note:The appearances will be same by the different models of air conditioners.
by johnson controls Working Temperature Range Ⅴ Working Temperature Range Working Temperature Range Indoor side state Outdoor side state Dry bulb temp. ℃ Wet bulb temp.℃ Dry bulb temp. ℃ Wet bulb temp. ℃ Rated. Cooling 27 19 35 24 Max. cooling 32 23 48 26 Min. cooling 21 15 18 — Rated. Heating 20 15 7 6 Max. heating 27 — 24 18 Min.
by johnson controls Maintenance Method Ⅵ Maintenance Method Warning! ① . Do turn off the unit and cut off the main power supply when cleaning the air conditioner, otherwise electric shock may happened. ② . Do not make the air conditioner wet or electric shock may be lead; Ensure that the air conditioner will not be cleaned by water rinsing under any circumstance. ③ . Volatility liquid like thinner or gasoline would damage the appearance of air conditioner.
by johnson controls Operating Instructions Ⅶ Operating Instructions * The temperature should not be set lower than what you need. This would lead to increase energy cost. * To distribute cool air throughout the room, adjust airflow direction as shown by the arrows (see picture) to diffuse cool air. * Clean the air filter every week for higher efficiency by professional. * Close window and door while operating the unit to prevent leakage of cooled air and save energy.
by johnson controls Operating Instructions * Check electrical system (voltage and frequency). Use the power supply indicated on the unit to operate the air conditioner and only fuses with specified capacity it should be done by professional. Do not use pieces of wire instead of fuse. * Do not insert objects into the air inlet or outlet when the air conditioner is running as it may cause damage or personal injury. Also pay special attention when children are around.
by johnson controls Malfunction Analyzing Ⅷ Malfunction Analyzing Warning ! Do not repair air conditioner by yourself for the incorrect repair would lead electric shock or fire. Please contact service center and had the unit repaired by specialized personnel. Check the following item before contacting to repair could save your time and cost.
by johnson controls 18
DECLARACION CE DE CONFORMIDAD SOBRE MAQUINAS FABRICANTE: JOHNSON CONTROLS MANUFACTURING ESPAÑA, S.L. DIRECCIÓN: Paseo Espronceda, 278, 08204 SABADELL Certificamos que el equipo descrito, ha sido diseñado, fabricado y probado de conformidad con los requisitos básicos de la Directiva de Equipos a presión 97/23/CEE y sus correspondientes módulos de aplicación.