Specifications

035-17377-000 REV A (0201)
Unitary Products Group 19
FIGURE 16 : FIELD WIRING DISCONNECT
TABLE 12: ELECTRICAL DATA 6-1/2 TON - STANDARD EFFICIENCY
Voltage
Compressors
OD Fan
Motors
FLA ea.
Blower Motor Supply
FLA
Electric Heater
Min. Circuit
Ampacity
(Amps)
Max Fuse
*
Size (Amps)
RLA
ea.
LRA
ea.
1.5 HP 2 HP
Model
Numbers
Rated
kW
Heater
Amps
1.5 HP 2 HP 1.5 HP 2 HP
208
14.1 110 1.5 6.2 8.2
None - - 40.9 42.9 50 50
2TP04510925 6.8 18.7 40.9 42.9 50 50
2TP04511825 13.5 37.5 54.6 57.1 60 60
2TP04512425 18.0 50.0 70.2 72.7 80 80
2TP04513625 27.0 70.8 96.2 98.7 100 100
230
14.1 110 1.5 6.2 8.2
None - - 40.9 42.9 50 50
2TP04510925 9.0 21.7 40.9 42.9 50 50
2TP04511825 18.0 43.3 61.9 64.4 70 70
2TP04512425 24.0 57.7 79.9 82.4 80 90
2TP04513625 34.0 81.8 110.0 112.5 110 125
460
7.1 54 0.8 3.1 4.1
None - - 20.7 21.7 25 25
2TP04510946 9.0 10.8 20.7 21.7 25 25
2TP04511846 18.0 21.7 30.9 32.2 35 35
2TP04512446 24.0 28.9 40.0 41.2 40 45
2TP04513646 34.0 40.9 55.0 56.2 60 60
575
5.8 44 0.6 2.4 3.6
None - - 16.7 17.9 20 20
2TP04510958 9.0 8.7 16.7 17.9 20 20
2TP04511858 18.0 17.3 24.7 26.2 25 30
2TP04512458 24.0 23.1 31.9 33.4 35 35
2TP04513658 34.0 32.7 43.9 45.4 45 50
*.
Maximum HACR breaker of the same AMP size is applicable.