Technical Guide

294604-YTG-B-0508
20 Johnson Controls Unitary Products
115°F 125°F
1200
77 44.6 5.3 22.6 17.6 12.7 - - - 40.0 5.8 21.1 16.1 11.2 - - -
72 40.6 5.2 29.7 24.8 19.8 14.9 - - 36.1 5.7 28.1 23.1 18.2 13.3 - -
67 36.5 5.2 36.5 31.9 27.0 22.0 17.0 - 32.1 5.7 32.1 30.2 25.2 20.3 15.3 -
62 34.4 5.1 34.4 34.4 32.4 27.4 22.5 17.5 30.9 5.6 30.9 30.9 29.5 24.5 19.6 14.6
57 32.8 5.1 32.8 32.8 32.0 27.1 22.1 17.2 29.2 5.6 29.2 29.2 28.9 24.0 19.0 14.1
1400
77 46.0 5.4 27.7 19.4 13.7 - - - 41.2 5.9 27.4 17.8 12.1 - - -
72 41.8 5.3 32.7 27.1 21.4 15.7 - - 37.2 5.8 31.0 25.3 19.6 13.9 - -
67 37.6 5.2 37.6 34.7 29.1 23.4 17.7 - 33.1 5.7 33.1 32.9 27.2 21.5 15.8 -
62 35.5 5.2 35.5 35.5 34.9 29.3 23.6 17.9 31.8 5.7 31.8 31.8 31.8 26.3 20.4 14.7
57 33.8 5.2 33.8 33.8 34.6 28.9 23.2 17.5 30.1 5.7 30.1 30.1 30.1 25.7 19.8 14.1
1600
77 47.4 5.4 32.7 21.1 14.7 - - - 42.4 5.9 33.7 19.4 12.9 - - -
72 43.1 5.3 35.7 29.3 22.9 16.5 - - 38.3 5.8 33.9 27.5 21.1 14.6 - -
67 38.7 5.3 38.7 37.6 31.2 24.8 18.4 - 34.1 5.7 34.1 34.1 29.2 22.7 16.3 -
62 36.5 5.2 36.5 36.5 37.5 31.1 24.7 18.3 32.8 5.7 32.8 32.8 32.8 28.1 21.2 14.8
57 34.8 5.2 34.8 34.8 37.1 30.7 24.3 17.9 30.9 5.7 30.9 30.9 30.9 27.4 20.6 14.2
1750
72 43.4 5.5 38.1 31.3 24.4 17.6 - - 38.7 6.0 36.5 29.6 22.7 15.8 - -
67 39.1 5.4 39.1 38.5 33.2 26.4 19.5 - 34.5 5.9 34.5 34.5 31.4 24.5 17.6 -
62 36.8 5.4 36.8 36.8 37.3 30.5 23.6 16.8 33.1 5.9 33.1 33.1 33.1 27.1 20.0 13.1
57 35.1 5.4 35.1 35.1 36.3 29.4 22.6 15.7 31.3 5.9 31.3 31.3 31.3 25.8 18.7 11.8
1900
72 43.8 5.6 40.5 33.2 25.9 18.6 - - 39.1 6.1 39.1 31.7 24.3 16.9 - -
67 39.4 5.6 39.4 39.4 35.2 27.9 20.6 - 34.9 6.0 34.9 34.9 33.7 26.3 18.9 -
62 37.1 5.5 37.1 37.1 37.1 29.8 22.5 15.2 33.5 6.0 33.5 33.5 33.5 26.1 18.7 11.3
57 35.4 5.5 35.4 35.4 35.4 28.1 20.8 13.5 31.6 6.0 31.6 31.6 31.6 24.2 16.9 9.5
1. These capacities are Net Capacities.
2. These ratings include the compressor, condenser fan and supply air blower motors.
DEZ048 (4.0 Ton) (Continued)
Air on
Evaporator Coil
Temperature of Air on Condenser Coil
Net
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
Net
Capacity
1
(MBh)
Total
Input
(kW)
2
Sensible Capacity (MBh)
CFM
WB
(°F)
Return Dry Bulb (°F) Return Dry Bulb (°F)
90 85 80 75 70 65 90 85 80 75 70 65