Technical Guide

294604-YTG-G-0511
66 Johnson Controls Unitary Products
Weights and Dimensions
Unit 4 Point Load Weight
Size
(Tons)
Model
Weight (lbs.) Center of Gravity 4 Point Load Location (lbs.)
Shipping Operating X Y A B C D
024
(2.0)
DEZ 379 374 23 23.25 92 85 95 102
DEQ 351 346 22.25 25 94 82 79 91
DEX 360 355 22.25 25 96 84 81 93
030
(2.5)
DEZ 380 375 23 22.25 88 82 99 106
DEQ 391 386 22.25 25 105 92 88 101
DEX 395 390 22.25 25 106 92 89 102
036
(3.0)
DEZ 384 379 23 22.25 89 83 100 107
DEQ 401 396 22.25 25 108 94 91 104
DEX 405 400 22.25 25 109 95 92 105
042
(3.5)
DEZ 405 400 23 21.25 90 83 109 118
DEQ 411 406 22.25 25 110 96 93 106
DEX 415 410 22.25 25 111 97 94 108
048
(4.0)
DEZ 406 401 21.5 21.75 98 80 101 123
DEQ 445 440 22.25 25 120 104 101 115
DEX 445 440 22.25 25 120 104 101 115
060
(5.0)
DEZ 410 405 23.5 22.75 95 92 107 110
DEQ 457 452 22.25 25 123 107 103 119
DEY 465 460 22.25 25 125 109 105 121
X
CENTER OF
GRAVITY
49-1/8
FRONT
OF
UNIT
Y
47-1/4
"D"
"C"
"B"
"A"
Unit Accessory Weights
Unit Accessory Model
Weight (lbs.)
Shipping Operating
Add Economizer All 45 40
Add Electric Heat
1
DEZ, DEQ, DEY, DEX 13 12
1. Weight given is for the maximum heater size available (25 kW).