Technical Guide
5005743-YTG-C-0815
2 Johnson Controls Unitary Products
DIMENSIONS
Models
1
Dimensions
2
Refrigerant
Connections
3,4,5
Height Width Opening Widths Line Size
ABCDLiquidVapor
CF18A*A1 19-1/2 14-1/2 13-1/2 13-1/2
3/8
3/4
CF18BXA1 19 17-1/2 16-1/2 16-1/2
CF24A*A1 19-1/2 14-1/2 13-1/2 13-1/2
CF24BXA1 19 17-1/2 16-1/2 16-1/2
CF24CXA1 21 21 20 20
CF30AXA1 21-5/8 14-1/2 13-1/2 13-1/2
CF30B*A1 23 17-1/2 16-1/2 16-1/2
CF30CXA1 21 21 20 20
CF30DXA1 25 24/1/2 23-1/2 23-1/2
CF36AXA1 25-1/2 14-1/2 13-1/2 13-1/2
CF36B*A1 25-5/8 17-1/2 16-1/2 16-1/2
CF36CXA1 23 21 20 20
CF36DXA1 25 24-1/2 23-1/2 23-1/2
CF42BXA1 25 17-1/2 16-1/2 16-1/2
7/8
CF42C*A1 25212020
CF42DXA1 25 24-1/2 23-1/2 23-1/2
CF48C*A1 27212020
CF48DXA1 27 24-1/2 23-1/2 23-1/2
CF60C*A1 33212020
CF60DXA1 32-3/4 24-1/2 23-1/2 23-1/2
CF64DXA1 32-3/4 24-1/2 23-1/2 23-1/2
1. Asterisk (*) denotes coil model is available as a flex coil or with factory installed TXV.
2. All dimensions are in inches.
3. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.
4. Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
Models
1
Dimensions
2
Refrigerant
Connections
3,4,5
Height Width Opening Widths Line Size
ABCDLiquidVapor
CM18A*A1 19-1/2 14-1/2 13-1/2 13-1/2
3/8
3/4
CM18BXA1 19 17-1/2 16-1/2 16-1/2
CM24A*A1 19-1/2 14-1/2 13-1/2 13-1/2
CM24B*A1 19 17-1/2 16-1/2 16-1/2
CM24CXA1 21 21 20 20
CM30A*A1 25-1/2 14-1/2 13-1/2 13-1/2
CM30B*A1 23 17-1/2 16-1/2 16-1/2
CM30CXA1 23 21 20 20
CM30DXA1 25 24/1/2 23-1/2 23-1/2
CM36AXA1 25-1/2 14-1/2 13-1/2 13-1/2
CM36B*A1 25-5/8 17-1/2 16-1/2 16-1/2
CM36C*A1 25 21 20 20
CM36DXA1 25 24-1/2 23-1/2 23-1/2
CM42C*A1 27 21 20 20
7/8
CM42DXA1 27 24-1/2 23-1/2 23-1/2
CM48C*A1 33 21 20 20
CM48D*A1 32-3/4 24-1/2 23-1/2 23-1/2
CM60C*A1 33 21 20 20
CM60D*A1 32-3/4 24-1/2 23-1/2 23-1/2
CM64DXA1 32-3/4 24-1/2 23-1/2 23-1/2
1. Asterisk (*) denotes coil model is available as a flex coil or with factory installed TXV.
2. All dimensions are in inches.
3. Refrigerant line sizes may require larger lines for extended line lengths. See Application Data part number 247077.
4. Adapter fitting must be field installed for other line set size.
5. See outdoor unit technical guide for proper line set size.
A
19-1/8”
(OPENING)
C (OPENING)
19-1/8"
D (OPENING)
21-1/2”
A0322-001
BOTTOM OPENING
DIMENSIONS
20-1/2”
B
A
B
19-1/8”
(OPENING)
C
(OPENING)
19-1/8"
D (OPENING)
A0323-001
BOTTOM OPENING
DIMENSIONS
20-1/2”
21-1/2”