Specifications
279550-YIM-E-0610
4 Johnson Controls Unitary Products
In Canada:
1. Canadian Electrical Code, CSA C22.1
2. Installation Codes, CSA - B149.1.
3. Local plumbing and waste water codes, and
4. Other applicable local codes.
Refer to unit application data found in this document.
After installation, gas fired units must be adjusted to obtain a 
temperature rise within the range specified on the unit rating plate.
If components are to be added to a unit to meet local codes, 
they are to be installed at the dealer’s and/or customer’s 
expense.
Size of unit for proposed installation should be based on heat 
loss/heat gain calculation made according to the methods of Air 
Conditioning Contractors of America (ACCA).
This furnace is not to be used for temporary heating of buildings 
or structures under construction.
Figure 1: Component Location
Direct Drive 
Condenser Fan Motor 
Highly Efficient Enhanced Copper 
Tube/Aluminum Fin Evaporator Coil 
Highly Efficient Enhanced Copper 
Tube/Aluminum Fin Condenser Coil 
Decorative Protective 
Coil Guard 
High Efficiency 
Compressor Rigidly 
Mounted 
Pilot Assembly
High Grade Aluminized In-Shot Burners 
Low Voltage Terminal Block 
Self-Diagnostic Controls 
Automatic Gas Valve (1/2" - NPTF)
High Voltage 
Terminal Block 
Power Draft Motor 
Direct Drive Blower Motor With 
Slide-Out Blower Assembly 
Heavy Gauge 
Removable Base Rails 
Rear and Bottom Return Air 
and Supply Airduct Openings 
Long Lasting Powder 
Paint Finish 
Blow-Through Design With 
Reliable Aluminized Steel 
Tubular Heat Exchangers 
Table 1: Unit Limitations
Size
(Tons)
Unit Voltage
Unit Limitations
Applied Voltage Outdoor DB Temp
Min Max Max (°F)
024
(2.0)
208/230-1-60 187 252 115
036
(3.0)
208/230-1-60 187 252 115
208/230-3-60 187 252 115
460-3-60 432 504 115
048
(4.0)
208/230-1-60 187 252 115
208/230-3-60 187 252 115
460-3-60 432 504 115