Weatherproof Temperature & Humidity Sensor YS8005-UC User Guide Rev 1.
Thank you for purchasing YoLink products and for entrus ng us with your smart home needs! Your 100% sa sfac on is our goal. If you experience any problems with se ng up your new YoLink Weatherproof Temperature & Humidity Sensor, please give us a chance to assist you, before returning your purchase. We at Customer Support are here for you.If you need any assistance installing , se ng up or using a YoLink product or our app. Find addi onal support and ways to reach us at: www.yosmart.
Contents A. B. C. D. E. F. G. H. I .
A. In the Box A. Weatherproof Temperature &Humidity Sensor B. Quick Start Guide A. B.
B. Introduc on The Weatherproof Temperature &Humidity Sensor is a smart two-in-one accurate thermometer and hygrometer device. By monitoring the real- me temperature and humidity levels in your home or business, you will know at any me the exact temperature and humidity levels in the space. You can set high and low levels alerts for temperature and humidity. When an alert level is reached, the LED will blink red once, and no fica ons will be sent to you via the YoLink app.
The LED light indicates the current status of the Weatherproof Temperature &Humidity Sensor : Blinking Red Once, then Green Once Device turned on Blinking Red And Green Alternately Restoring to Factory Defaults Blinking Green Connec ng to Cloud Slow Blinking Green Upda ng Blinking Red Once Device alerts or device is connected to the cloud and is func oning normally Fast Blinking Red Every 30 Seconds Ba eries are low; please replace the ba eries (see page 15) 3
C. Set Up C-1. Set Up - First-Time YoLink Users (Exis ng users proceed to C-2. Add Device, next page) 1 Download the YoLink app through Apple App Store or Google Play Store (Search in the store or use the QR code on the right) Apple iPhone or tablet that is iOS 9.0 or higher, or an Android phone or tablet that is Android 4.4 or higher 2 Log in to the YoLink app Create a new account if required 3 The YoLink Hub is required to set up your Weatherproof Te m p e ra t u r e & H u m i d i t y Sensor.
C-2. Add Device ” bu on, then scan QR 1 Ta p “ Code on the device. Follow the steps to add the device Weatherproof TH Sensor Model: YS8005-UC Ba ery: 2 AAA, 3V DC FCC ID: 2ATM78005 Made in China 2 Press the SET bu on once to turn on the device.
C-3. Device Placement Wall-moun ng: hang the sensor from the wall, on a nail or screw or other secure object, using the moun ng ring Surface-, Shelf- or countertop-moun ng: place the sensor on a stable surface so that it will not fall off or be knocked down 1. The sensor must NOT be submerged 2. For accurate readings, do not obstruct the openings on the sensor 3. Do not place the sensor on or near sources of extreme heat or cold 4.
D. Using the YoLink App D-1.
Sensor Refresh Frequency Both temperature and humidity values refresh when one of the following condi ons are met: a. The SET bu on has been pressed b. At least 0.9°F(0.5°C) change over a period longer than 1 minute c. At least 3.6°F(2°C) change within 1 minute SET Bu on d. At least 10% change over a period longer than 1 minute e. Device alert level reached or restored to normal range d.
D-2. Details Page a. Device Type b. Rename the Device c. Choose a Room for device d. Alert Se ngs - Enable or disable alerts a. Set alert range for temperature or humidity b. Set re-no fica on interval a er a temperature or humidity alert (refer to page 10) e. A calibra on Value for temperature or humidity f. Switch Temperature Display Mode: °F / °C g. Add/Remove from favorites h. Historical Log of temperature and humidity alerts, logged with date & me i. Real- me Status: Normal, Warning j. Device Model k.
Alert Settings h. a. b. d. a. Enable or disable alert - Receive no fica ons when the temperature value or humidity value is below the low alert value or above the high alert value set below b. Slide to set the low temperature alert value (Default is 64°F (18°C) c. Slide to set the High temperature alert value (Default is 95°F (35°C) d. Slide to set the low humidity alert value (Default is 0%) e. Slide to set the high humidity alert value (Default is 100%) c. e. f. g. f.
D-3. Automa on Go to the “Smart” screen, tap “Automa on” The Weatherproof Temperature & Humidity Sensor can be set as a trig ger only, with four trig ger op ons: Low Temperature Alert; High Temperature Alert; Low Humidity Alert; High Humidity Alert a. b-1 b-2 b-5 b.
D-4. Voice Assistants C o n n e c t Yo L i n k w i t h A l exa to m o n i to r t h e stat u s o f yo u r d ev i c e s t h ro u g h vo i c e co m m a n d s Tap “ ” in the upper le corner to go to My Profile Go to Se ngs > Voice Assistants for the applicable voice assistant integra on guide YoLink Weatherproof Temperature & Humidity Sensor is integrated with Alexa, and is also integrated with IFTTT.
E. Maintenance E-1. Firmware Update To ensure our customers have the best user experience, we highly recommend you update to the newest version firmware when an update is available In “Firmware”, if a new version is listed as available (#### ready now), click it to start the firmware update process The device's firmware will be updated automa cally within 1 hours (maximum).
E-2. Factory Reset Factory reset will erase all of your se ngs and restore it to factory defaults.
E-3. Replacing the Ba eries Tools Required: Small Philips Screwdriver Tweezers 1. To maintain the water ght design of your Weatherproof Temperature & Humidity Sensor, use extreme care and follow the ba ery replacement instruc ons closely 2. Do not mix old and new ba eries 3. Make sure that the bo om shell and sealed rubber pads are ghtly secured.
3 Remove the two old ba eries 4 Install two new AAA ba eries 2 x AAA 5 Close and secure the base by reinstalling and ghtening the four screws 6 Re a a c h t h e fo u r sealing rubber pads 16
F. Specifica ons Voltage: 3V DC (2 - lithium non-rechargeable AAA ba eries) Device Current Draw: ≤ 135mA (opera ng), ≤ 35uA (standby) Sensor Types: Temperature, Humidity Temperature Value Accuracy: 0.1 (°F/°C) Humidity Value Accuracy: 0.1% Alert Temperature: -22°F - 158°F (-30°C - 70°C) Alert Humidity: 0% - 100% IP Ra ng: IP67 Dimensions: 2.44 x 2.44 x 0.
Temperature Error (Typical): -40 °F - 14 °F, ±1.44°F (-40 °C - -10 °C, ±0.8°C) 14°F - 41°F, ± 0.72 °F ( -10°C - 5°C, ±0.4°C) 41°F - 140°F, ± 0.36 °F (5°C - 60°C, ±0.2°C) 140°F - 176°F, ± 0.72 °F (60°C - 80°C, ±0.4°C) Temperature Error (Maximum): -40 °F - -4 °F, ±2.7°F (-40 °C - -20 °C, ±1.5°C) -4°F - 32°F, ± 1.8 °F ( -20°C - 0°C, ±1°C) 32°F - 41°F, ± 0.9 °F (0°C - 5°C, ±0.5°C) 41°F - 140°F, ± 0.72 °F (5°C - 60°C, ±0.4°C) 140°F - 176°F, ± 1.35 °F (60°C - 80°C, ±0.
G. Troubleshoo ng Symptoms: 1. Device is offline.
H. Warning Please install, operate and maintain the Weatherproof Temperature & Humidity Sensor only as outlined in this manual. Improper use may damage the unit and/or void the warranty U s e o n l y n e w, n a m e b ra n d , l i t h i u m n o n - r e c h a r g e a b l e A A A b a e r i e s Do not use rechargeable ba eries Do not use zinc blend ba eries Do not mix new and old ba eries Do not puncture or damage ba eries.
Install or use this device only in clean environments. Extremely dusty or dirty environments may prevent the proper opera on of this device, and will void the warranty If your Weatherproof Temperature & Humidity Sensor does get dirty, please clean it by wiping it down with a clean, dry cloth.
If you have any difficul es installing or using your Weatherproof Temperature & Humidity Sensor, please contact our Customer Service department during business hours: US Live Tech Support: 1-949-825-5958 M-F 9am - 5pm PST Email: service@yosmart.com YoSmart Inc.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons, may cause harmful interference to radio communica ons.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica ons to this equipment. Such modifica ons could void the user’s authority to operate the equipment FCC RF Radia on Exposure Statement This equipment complies with FCC RF radia on exposure limits set forth for an uncontrolled environment.