6. Reliability/Safety Requirements
6.1 Reliability Test Requirements
6.2 Safety Test Requirements
Test Conditions Sample
Requirements
High temperature exposure
70 +/- 2 °C for 8 weeks 5
No leakage, No
fire, No
explosion
Thermal Cycling
Shock-IEC 60086-5
Repeat the following temperature cycle 10 times:
Heat to +70°C within 30 minutes, hold for 4 hours.
Cool to +20°C within 30 minutes, hold for 2 hours.
Cool to -20°C within 30 minutes, hold for 4 hours.
Heat to +20°C within 30 minutes
After the 10
th
cycle store batteries for 7 days
5
Short Circuit-IEC 60086-5
Connect positive and negative terminals using circuitry
with a resistance of less than 0.1 Ohm. Discharge for
24 hours.
5
No fire, No
explosion
No fire, No
explosion
Over Discharge Test
Discharge one fresh battery under IEC 60086-2, with
highest MAD value until on-load voltage falls to (n x
0.6v)”n” is the number of cells. Then, connect 3 fresh
batteries of the same brand, type and origin in series.
Continue discharge until voltage falls to four times (n x
0.6v).
The value of the resistor shall be approximately four
times the lowest value from the resistive load
IEC60086-2.The final value of the resistor shall be the
nearest value to that prescribed in 6.4 of IEC 60086-1
20
Safety Vent Test
Put 4 fresh batteries in a series ring connection with
one battery with reversed polarity for 1 day. Remove
batteries from circuit and observe for 7 days. Safety
vent shall operate.
20
Test Conditions Sample
Requirements
Lot Capacity
Discharge continuously using a load resistance of 75
ohm (± 0.5%) to a closed circuit voltage of 0.9V.
9 ≥1100mAh
Variable Frequency
Vibration- IEC 60086-5
Simple harmonic, maximum excursion of 1.6 mm.
Modulate frequency up and down at 1 Hz/min between
10 and 55 Hz. Test in 3 mutually perpendicular
directions for 90 ± 5 minutes per direction
5
No leakage, No
fire, No
explosion
Low Temperature Storage
-20 2C for 24 hrs
5
High Temperature Storage
55 2C for 100 hrs
5
Corrosion Resistance
60 ± 2C / 90± 5% RH for 7 days
5
Drop Test -IEC 60086-5
Drop at 1 m height onto concrete 6 times, twice on
each the battery’s 3 axes.
5
Storage after partial use
Discharge a fresh battery under IEC 60086-2 until the
service life falls by 50%of MAD value, followed by
storage at(45±5)℃for 30 days
5
Transportation-shock
Half sine wave shock with 75 g
n
in first 3 Milliseconds,
and 125-175 g
n
peak acceleration shock pulse, shock
one time in three perpendicular directions
g
n=
9,80665m/s²
5