Recommended with: Siren Horn Outdoor Alarm Controller YS7104-UC Installa on & User Guide Rev 1.
Thank you for purchasing YoLink products and for entrus ng us with your smart home needs! Your 100% sa sfac on is our goal. If you experience any problems with se ng up your new YoLink Outdoor Alarm Controller, please give us a chance to assist you, before returning your purchase. We at Customer Support are here for you.If you need any assistance installing , se ng up or using a YoLink product or our app. Find addi onal support and ways to reach us at: www.yosmart.
Contents A. B. C. D. E. F. G. H. I . J. K.
A. In the Box A. Box 1 A. Outdoor Alarm Controller B. Moun ng Hook C. Quick Start Guide C. Ba eries are not included. This device requires four AA ba eries. For outdoor applica ons, B. especially extreme hot or cold temperature, we recommend lithium type AA ba eries, for op mal performance. Box 2 (Op onal Accessory) A. A.
B. Introduc on The YoLink Outdoor Alarm Controller is a smart device that can control a 12 VDC siren horn or any other 12VDC, maximum 400mA (resis ve) alarm devices remotely with the YoLink app on your smartphone or tablet or using the SET bu on on the device. Pressing "Ac vate Alarm" or "Silence Alarm" on the app will ac vate or silence the alarm device.
The LED light indicates the current status of the Outdoor Alarm Controller: Blinking Red Once, Then Green Once Device turned on Blinking Red And Green Alternately Restoring to Factory Defaults Blinking Green Once Ac vate the siren horn Blinking Green Connec ng to Cloud Slow Blinking Green Upda ng Fast Blinking Green Establishing Connec on with YoLink System (YoLink Control) Blinking Red Once Silence the siren horn or device is connected to the cloud and is func oning normally Fast Blinking Red Remov
C. Set Up C-1. Set Up - First-Time YoLink Users (Exis ng users proceed to C-2. Add Device, next page) 1 Download the YoLink app through Apple App Store or Google Play Store (Search in the store or use the QR code on the right) Apple iPhone or tablet that is iOS 9.0 or higher, or an Android phone or tablet that is Android 4.4 or higher 2 Log in to the YoLink app 1.
C-2. Add Device ” bu on, then scan QR 1 Ta p “ Code on the device. Follow the s t e p s tYou o amust d d t press h e d e“Bind v i c eDevice” to pair the device to your account 2 Press the SET bu on once to turn on the device a er installa on. The Status LED will blink red once, then green several mes, indica ng your device has connected to the cloud and is ready to use SET Bu on 1. You will need to press the SET bu on once again if the device failed to connect to the cloud 2.
Your applica on may vary. We recommend protec ng the wiring and connec ons from the elements and from damage. If prac cal, install the Alarm Controller and wiring indoors, or inside an outdoor-rated enclosure. See page 16 for alterna ve installa on methods including a junc on box. For example, install the Alarm Controller in a suitable plas c outdoor-rated enclosure or electrical junc on box, and mount the Siren Horn (or your alarm device) to the cover or plate of the enclosure or box.) D. Installa on D-1.
D-2. Instruc ons for installing the Outdoor Alarm Controller for use with a new Siren Horn (Model: ES-626) D-2-1. How to install the Siren Horn 1. These Tools may be Required A. Phillips screwdriver B. Pencil C. Wall Screws (3) D. Drywall Anchors (M6, 3) E. Drill A. B. E. C. D. 2. Begin Installa on 1 Place the siren horn base at the desired loca on, then mark an outline (with a pencil, tape, etc.
2 Mount the siren base to the wall with anchors and/or screws (not included) appropriate for the moun ng surface Plas c Drywall Anchors (included) For drywall and other hollow wall installa ons - Install the wall anchors first if it is a drywall installa on 8
D-2-2. How to Connect the Siren Horn to the Controller 1 A er the siren horn is securely installed (all screws ght, etc.
D-3. Instruc ons for installing the Outdoor Alarm Controller for use with a n o n -Yo L i n k a l a r m o r a u d i b l e / v i s i b l e d ev i c e ( N o n - s m a r t , 1 2 V D C, Maximum 400mA Alarm Current only!) 1. These Tools may be Required Wire Cu er/Stripper U lity Knife Scissors Wire Nuts or Connectors (2) Electrical Tape 1. Your alarm device must be 12 VDC, maximum 400mA working current, non-smart, and func onal 2. Wire nuts (twist-on connectors) are the recommended wire splicing method.
D-3-1. How to Prepare for I n sta l l a o n o f t h e Controller 2 Use a wire cu er/stripper to remove the connector on the new controller. Use care to avoid cu ng or nicking the antenna 3 U s i n g a w i re s t r i p p e r, remove the insula on on each conductor, leaving roughly half an inch of exposed conductor OR 1 U s i n g a s c i s s o rs o r u l i t y knife, carefully remove t h e o u te r j a c ket / i n s u l a o n o n t h e ca b l e .
D-3-2. How to Prepare for Installa on of the alarm device 2 Using a wire stripper or u lity knife, carefully remove the outer jacket/insula on on the cable.
D - 3 - 4 .
D-4. Test the Controller and Siren Horn (or other alarm device) Test the controller several mes by pressing the SET bu on and confirm the siren horn* ac vates and silences properly. Then, use the YoLink app to ac vate and sil ence the siren horn* If Not Working Properly: WARNING!! - If you are unable to get the To avoid damage to hearing, do NOT stand near the siren or any controller and/or siren horn* to audible alarm device while it is ac vated! operate correctly, double-check the installa on as needed.
D-5. Installa on Methods (Outdoor Electrical Junc on Box) Please refer to device environmental opera ng range informa on on page 31. Use this device outside the recommended ranges at your own risk Example of installa on instruc ons for a commercial siren or siren/strobe. Please note the junc on box. this is where the wire and connec ons/splices would be protected Outdoor Electrical Junc on Box 1. Please refer to device dimensions informa on on page 33 2.
E. Using the YoLink App E-1.
E-2. Details page a. Device Type b. Rename the Device c. Choose a Room for device d. Add/Remove from favorites e. Device alarm history Historical log of alarm-ac vated, logged with trigger events, date & me f. Set the dura on once an alarm occurs - Default is set to 30 seconds, and maximum is 30 minutes g. Connec on status of alarm controller and Hub h. Device Model i. Device EUI (unique) j. Device SN (unique) k. Connec on Signal Status of controller and Hub: Strong; Good; Weak l.
E-3. Device Alarms E-3-1.
E-3-3.
E-4. Automa on (Set Up Rules For “If This Then Do That”) T h e m o s t p o p u l a r u s e fo r o u r O u t d o o r A l a r m C o n t ro l l e r i s t o a c v a t e t h e a l a r m automa cally in the response to events such as door has been opened, mo on has been d e t e c t e d ; w a t e r l e a k h a s b e e n d e t e c t e d , e t c . G e n e ra l l y, y o u h av e t w o o p o n s fo r t h i s : Op on 1. Configure an Automa on in the app.
a. b-1 b-2 b-5 b. Add an automa on b-1 Edit name b-2 Edit trigger b-3 Edit behavior (You must have at least one ac on device, or you cannot set a behavior) b-4 Edit when (Set a me range for the automa on (always or during specific days or mes) b-5 Tap to save the se ngs b-3 Swipe Le c. b-4 c. Click to edit the automa on a. Tap the “+” icon to add an automa on 1. Tap “ ” bu on to enable or disable the automa on 2.
E-5. Alarm Strategy Set up rules to ac vate alarm when a device alert is detected (such as Water Leak Sensor, Mo on Sensor, etc.). Follow instruc ons below to enable Device Alert first Tap “ ” in the upper le corner to go to My Profile Go to Se ngs > Alarm Strategy for no fica ons preferences se ngs (Only support Host account) b. a-1 a-2 a.
E-6. Voice Assistants Connect YoLink with third-party voice assistants to control (turn on or turn off ) or monitor the status of your devices through voice commands Tap “ ” in the upper le corner to go to My Profile Go to Se ngs > Voice Assistants for the applicable voice assistant integra on guide 1. The Outdoor Alarm Controller works with Alexa and Google Assistant and also with IFTTT.com 2. For Alexa and Google, it can be controlled by voice command, from the associated app (e.g.
F. About YoLink Control YoLink Control is our unique device-to-device control technology. Using YoLink Control, YoLink devices can be controlled without the Hub or an internet connec on. (Use of YoLink Control is op onal; you can use the Automa on feature in the app OR use YoLink Control, but YoLink Control offers the benefit of opera on without the Hub or internet connec on.) One device controls another, directly. A device that sends out commands is called the controller.
2 To c o n fi g u r e a n O u t d o o r A l a r m C o n t r o l l e r a s t h e r e s p o n d e r, Press and hold the SET bu on for 5-10 seconds un l the LED quickly blinks green, then, release the bu on b.
F-1-1. Opera on W h e n t h e Wa t e r L e a k S e n s o r detects water, the Outdoor Alarm Controller will now immediately ac vate siren horn or alarm device. The siren horn or alarm device will remain ac vated un l silenced via the app or using the SET bu on of controller; the restoral of the Water Leak Sensor to normal (no water detected) does not silence the siren horn or alarm device More advanced sequences, controlling mul ple outputs (e.g.
F-2.
G. Maintenance G-1. Firmware Update To ensure our customers have the best user experience, we highly recommend you update to the newest version firmware when an update is available In “Firmware”, if a new version is listed as available (#### ready now), click it to start the firmware update process You may use your device during the update as it is performed in the background.
G-2. Factory Reset the Outdoor Alarm Controller Factory reset will erase all of your se ngs and restore it to factory defaults.
G-3.
H. Specifica ons H-1.
Dimensions: Unit: inches (millimeters) 0.98 (24.8) 3.24 (82.2) 0.31 (7.8) 0.94 (24.0) 0.26 (6.7) 0.37 (9.5) 2.68 (68.2) 0.24 (6.2) 3.45 (87.7) 3.19 (81.0) 3.45 (87.7) 3.19 (81.0) 3.24 (82.2) 0.94 (24.0) 0.98 (24.
H-2. Siren Horn Working Voltage: 12V DC Device Current Draw: ≤ 500mA (on), 0mA (standby) Siren Volume: 110 dB (@0.3m) Alarming Dura on: Maximum 30 minutes per alarm me Dimensions: 4.06 x 3.90 x 2.56 inches (103 x 99 x 65 millimeters) (L x W x D) Connec on Cable Length: ~ 1.
I. Troubleshoo ng Symptom: 1.
J. Warning P l e a s e i n s t a l l , o p e ra t e a n d m a i n t a i n t h e O u t d o o r A l a r m C o n t ro l l e r o n l y a s o u t l i n e d i n t h i s m a n u a l .
If yo ur Outdoor Alarm Controller does get dirty, please clean it by wiping it down with a clean, dr y cloth. Do not use strong chemicals or detergents, which may discolor or damage the ex terior and/or damage the electronics, voiding the warranty Do not install or use this device where it will be subjected to physical impacts and/or strong vibra on.
If you have any difficul es installing or using YoLink products, please contact our Customer Service department during business hours: US Live Tech Support: 1-949-825-5958 M-F 9am - 5pm PST Email: service@yosmart.com YoSmart Inc. 17165 Von Karman Avenue, Suite 105, Irvine, CA 92614 Warranty 1 Year Limited Electrical Warranty YoSmart warrants to the original residen al user of this product that it will be free from defects in materials and workmanship, under normal use, for 1 year from the date of purchase.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protec on against harmful interference in a residen al installa on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc ons, may cause harmful interference to radio communica ons.
Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica ons to this equipment. Such modifica ons could void the user’s authority to operate the equipment. FCC RF Radia on Exposure Statement This equipment complies with FCC RF radia on exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or opera ng in conjunc on with any other antenna or transmi er.