Manual
  <7.GeneralSpecications>
7-5
IM 01C50B01-01E
Factorysetting(◊)
Tag No. Left blank if not specied in order Unit of calibration range “°C” if not specied in order
Input sensor type “Pt100, 3-wire” if not specied in order Damping constant 2 seconds
Lower calibration range “0” if not specied in order Sensor burnout High side (110%, 21.6 mA DC) 
*
1
Upper calibration range “100” if not specied in order Output when transmitter fails High side (110%, 21.6 mA DC) *
2
*1:  When option code C1 is specied, Low takes effect (–2.5%, 3.6 mADC).
*2:  When option code C1 is specied, Low takes effect (–5%, 3.2 mADC or less).
7.2 ModelandSufxCodes
Model BasicSpecicationCodes Description
YTA110
YTA310
YTA320
 · · · · · · · · · · · · · · · · · · · · · · 
 · · · · · · · · · · · · · · · · · · · · · · 
 · · · · · · · · · · · · · · · · · · · · · · 
Temperature transmitter (1 input type)
High precision temperature transmitter (1 input type)
High precision temperature transmitter (2 input type)
Output 
signal
-D · · · · · · · · · · · · · · · · · · · ·
-E · · · · · · · · · · · · · · · · · · · ·
-F  · · · · · · · · · · · · · · · · · · · ·
4 to 20mA DC output, BRAIN communication type
4 to 20mA DC output, HART communication type
FOUNDATION Fieldbus communication type (YTA320 only) 
— A· · · · · · · · · · · · · · · · · · Always A
Electrical connection 0 · · · · · · · · · · · · · ·
2 · · · · · · · · · · · · · ·
3 · · · · · · · · · · · · · ·
4 · · · · · · · · · · · · · ·
G1/2 female
1/2 NPT female
Pg13.5 female
M20 female
Built-in indicator D· · · · · · · · · · ·
N· · · · · · · · · · ·
Digital indicator
None
Mounting bracket B· · · · · · ·
D· · · · · · ·
J · · · · · · ·
K· · · · · · ·
N· · · · · · ·
SUS304 Stainless steel 2-inch horizontal pipe mounting *
1
SUS304 Stainless steel 2-inch vertical pipe mounting *
1
SUS316 Stainless steel 2-inch horizontal pipe mounting 
*1
SUS316 Stainless steel 2-inch vertical pipe mounting 
*1
None
Additional specications
/
Additional specications
*1:  Use bolts for wall mounting.
7.3 OptionalSpecications
Item Descriptions Code
YTA110
YTA310
YTA320
Lightning protector Power supply voltage: 10.5 to 32 V DC
Allowable current: Max. 6000A(1×40μs), repeating 1000A(1×40μs) 100 times
A
 
Painting Coating change Epoxy resin coating
X1
 
Color change Amplier cover only Munsell renotation code: NI1.5 Black
P1
 
Munsell renotation code: 7.5BG4/1.5, Jade green
P2
 
Metallic silver
P7
 
Amplier and Terminal covers Munsell renotation code: 7.5R4/14 Red
PR
 
SUS316 exterior parts Exterior parts on the amplier housing (name plates, tag plate, screws)  
will become SUS316 stainless steel 
*3
HC
 
Stainless Steel Housing*
1
Housing Material: SCS14A Stainless steel
E1
 
Wired tag plate SUS304 stainless steel tag plate wired onto transmitter 
*4
N4
 
Calibration Unit Addition of Degree F and Degree R unit
D2
 
Output signal low-side in
Transmitter failure*
2
Output signal low-side: –5 %, 3.2 mA DC or less.
Sensor burnout is also set to ‘Low’: –2.5 %, 3.6 mA DC
C1
 
NAMUR NE43
compliant*
2
Output signal limits:
3.8 mA to 20.5 mA
Failure alarm down-scale: output status at CPU failure and 
hardware error is –5%, 3.2 mA or less.
Sensor burnout is also set to ‘Low’: –2.5%, 3.6 mA
C2
 
Failure alarm up-scale: output status at CPU failure and 
hardware error is 110%, 21.6 mA or more.
Sensor burnout is also set to ‘High’: 110%, 21.6 mA
C3
 
Data Conguration*
2
Description into “Descriptor” parameter of HART protocol. (max. 16 characters)
CA
 
Sensor matching function*
2
RTD Sensor matching function
CM1
×
*1 :   Not applicable with other option codes, except for A, C1, D2 and CM1.
*2 :   Not applicable for output signal code F.
*3 :  This specication is not included in option code E1. Select HC for SUS316 exterior parts regardless of E1.
*4 :  When HC is selected, the material is SUS316 stainless steel.