User Manual
<9. General Specications>
9-1
IM 01C50T02-01E
9. General Specications
9.1 Standard Specications
For items other than those described below,
refer to IM 01C50B01-01E.
Applicable Model:
YTA320
Accuracy
See Table 9.1 in Page 9-4.
Ambient Temperature Effect per 10°C Change
See Table 9.2 in Page 9-5.
Output Signal:
Digital communication signal based on
FOUNDATION Fieldbus protocol.
Supply Voltage:
9 to 32 V DC for general use and ameproof
type
9 to 24 V DC for intrinsically safe type Entity
model
9 to 17.5 V DC for intrinsically safe type FISCO
model
Conditions of Communication Line:
Supply Voltage: 9 to 32 V DC
Supply Current: 16.6 mA (max)
Functional Specications:
Functional specications for Fieldbus
communication conform to the standard
specications (H1) of
FOUNDATION Fieldbus.
Function Block:
Four AI function blocks
Four DI function blocks
One/Two PID function blocks (option)
Link Master funtion
< Settings When Shipped >
Sensor type ‘Pt100, 3 wire system’ (for both inputs), or as specied in
order.
Tag Number (PD tag) ‘TT1001’ unless otherwise specied in order. (Not
engraved on tag plate in such case.) *
1
Output Mode (L_TYPE) ‘Indirect’ unless otherwise specied in order
Calibration Range (XD_SCALE) Lower/Higher Range Value ‘0 to 100’, or as specied in order
Unit of Calibration Range Selected from °C and Kelvin. (Only one unit can be
specied.) When optional code /D2 is specied, °F and °R
can also be specied.
Output Scale (OUT_SCALE) Lower/Higher Range Value ‘0 to 100%’
Damping Time Constant (PV_FTIME of TB) ‘2 sec.’
Node Address (in hexadecimal) ‘0 × F3’ unless otherwise specied in order
BOOT_OPERAT_FUNCTION_CLASS ‘BASIC’ unless otherwise specied in order