User Manual
6-10
IM 04L21B01-17EN
List of Registers
Register Description Supplementary Information Type Access Simultaneous
Access
Write Read
406061 Internal switch 1 OFF: 0. ON: 1. INT16 R –
406062 Internal switch 2 OFF: 0. ON: 1. INT16 R –
406063 Internal switch 3 OFF: 0. ON: 1. INT16 R –
406064 Internal switch 4 OFF: 0. ON: 1. INT16 R –
406065 Internal switch 5 OFF: 0. ON: 1. INT16 R –
406066 Internal switch 6 OFF: 0. ON: 1. INT16 R –
406067 Internal switch 7 OFF: 0. ON: 1. INT16 R –
406068 Internal switch 8 OFF: 0. ON: 1. INT16 R –
406069 Internal switch 9 OFF: 0. ON: 1. INT16 R –
406070 Internal switch 10 OFF: 0. ON: 1. INT16 R –
406071 Internal switch 11 OFF: 0. ON: 1. INT16 R –
406072 Internal switch 12 OFF: 0. ON: 1. INT16 R –
406073 Internal switch 13 OFF: 0. ON: 1. INT16 R –
406074 Internal switch 14 OFF: 0. ON: 1. INT16 R –
406075 Internal switch 15 OFF: 0. ON: 1. INT16 R –
406076 Internal switch 16 OFF: 0. ON: 1. INT16 R –
406077 Internal switch 17 OFF: 0. ON: 1. INT16 R –
406078 Internal switch 18 OFF: 0. ON: 1. INT16 R –
406079 Internal switch 19 OFF: 0. ON: 1. INT16 R –
406080 Internal switch 20 OFF: 0. ON: 1. INT16 R –
406081 Internal switch 21 OFF: 0. ON: 1. INT16 R –
406082 Internal switch 22 OFF: 0. ON: 1. INT16 R –
406083 Internal switch 23 OFF: 0. ON: 1. INT16 R –
406084 Internal switch 24 OFF: 0. ON: 1. INT16 R –
406085 Internal switch 25 OFF: 0. ON: 1. INT16 R –
406086 Internal switch 26 OFF: 0. ON: 1. INT16 R –
406087 Internal switch 27 OFF: 0. ON: 1. INT16 R –
406088 Internal switch 28 OFF: 0. ON: 1. INT16 R –
406089 Internal switch 29 OFF: 0. ON: 1. INT16 R –
406090 Internal switch 30 OFF: 0. ON: 1. INT16 R –
407833 to
407834
Lot number Valid range: 0 to 99999999 INT32_L R/W
407835 to
407851
Batch number Up to 17 registers (up to 33 characters with '¥0'
termination). The batch number must be 32
characters or less.
STR34 R/W
409503 Memory start or stop Stop: 0. Start: 1. INT16 R/W
409504 Alarm acknowledge Applies to all alarms.
<When writing>
Execute alarm ACK: 1 (fixed)
<When reading (alarm summary)>
Alarm off: 0. Alarm illuminated: 1. Alarm blinking
(occurring): 2. Alarm blinking (not occurring): 3
INT16 R/W
409506 Computation operation <When writing>
Stop: 0. Start: 1. Reset: 2. Computation dropout
ACK: 4.
<When reading>
Stop: 0. Start: 1.
INT16 R/W
409512 Manual sampling start
or other action
Manual sampling: 0. Manual trigger: 1. Snapshot:
2.
INT16 W
410601 Preset message writing Message number (1 to 100) INT16 W
410602 Message write destination
0: All groups. 1 to 10: Specified group number.
INT16 W
410603 Specified value. INT16 W
410604 to
410610
(Reserved) Preset
message
- - -
6.3 Modbus Protocol Specifications