User Manual

4-24
IM 04L21B01-17EN
Status Information
The IS command is used to output the data. The output format varies between IS0
and IS1.
The operation status of the recorder is output.
For details on the status information, see section 5.2, “Bit Structure of the Status
Information.”
Output for the IS0 command
Syntax
EACRLF
aaa.bbb.ccc.dddCRLF
ENCRLF
aaa
Status information 1 (
000
to
255
)
bbb
Status information 2 (
000
to
255
)
ccc
Status information 3 (
000
to
255
)
ddd
Status information 4 (
000
to
255
)
Example
EA
000.000.032.000
EN
Output for the IS1 Command
Syntax
EACRLF
aaa.bbb.ccc.ddd.eee.fff.ggg.hhhCRLF
ENCRLF
aaa
Status information 1 (
000
to
255
)
bbb
Status information 2 (
000
to
255
)
ccc
Status information 3 (
000
to
255
)
ddd
Status information 4 (
000
to
255
)
eee
Status information 5 (
000
to
255
)
fff
Status information 6 (
000
to
255
)
ggg
Status information 7 (
000
to
255
)
hhh
Status information 8 (
000
to
255
)
Example
EA
000.000.032.000.000.000.000.000
EN
Status information 3, 4, 7, and 8 are edge operation. They are cleared when read by
the IS command.
Status information 1, 2, 5, and 6 are level operation. They are not cleared when read.
They are cleared when the event clears.
The status information is made up of bits that correspond to each event. Each bit can
be turned ON/OFF with a filter.
If an event occurs for a bit set to OFF by the filter, status information 3, 4, 7, and 8
discard the event. Status information 1, 2, 5, and 6 hold the event.
The default filter setting is all ON.