Owner's manual

2-14
IM 04L21B01-63EN
Changing the Grid Display
To select the grid type, click one of the grid density icons on the toolbar, or click [Y-Axis]
on the menu bar.
Switch the grid density
Grid Display Examples
[Y-Axis] - [Standard Grid] [Y-Axis] - [Dense Grid1] [Y-Axis] - [Dense Grid2]
Waveform Display Limit (clip)
To enable the waveform display limit, click the clip icon ( ) on the toolbar, or select
[Y-Axis] - [Clip] on the menu bar. When the limit is enabled, the waveform’s Y-axis display
range is limited to the minimum and maximum values that you have set under [General
Display Settings] - [Scale]. Measured values that are less than the minimum value are
set to the minimum value and values that are greater than the maximum value are set to
the maximum value.
Example in which Display Limit is Enabled
Example in which Display Limit is Disabled
Turn ON/OFF the Alarm Display
1. Click here ([View] - [Alarm]).
2. The alarm is displayed.
Alarm display
No alarm
Alarm occurrence
Alarm 1
Alarm 2
Alarm 3
Alarm 4
2.2 Displaying the Waveform