Operation Manual
5-6
IM 1F5B2-01E
5.5 Signal cable end finish procedure
For finishing signal cable end, following the procedure as below:
IMPORT ANT
The length of signal cable must be less than 20m.
(1) Remove the outer jacket, outer shield and inner
jacket as shown in the figure below.
10
65
Inner shield
Outer jacket
Inner
jacket
Outer shield
45
35
25
White
Red
55
(A)
(G)
(B)
(C)
Blue tubing
Black tubing
(A)
(G)
(B)
(C)
Heat shrinkable tubing
A
Tip
Label
7
Heat shrinkable tubing
Unit : mm
(2) Remove inner shield, intertwine two drain
wires, and cut each tip.
(3) Remove the wire insulation and twist each wire
as shown below.
(4) Insert insulation tubing over B and G until it
stops inside the shield. Cut the tubing off
leaving only 0.2 inch (5mm) of the inner shield
exposed. Remove 0.2 inch of insulation from
the tips of the two wires.
(5) Insert the heat shrinkable tubing as shown
below.
(6) As shown in the figure below, install the tip on
each wire and label of the sign which corre-
sponds to the each line.
(7) Heat all of shrinkable tube with a heat blower
or heat gun, and then shrink them.