User Manual
3-4
IM 04L61B01-01EN
This section explains how to set each setup item individually.
Changing the Active Display Group
When you open a data file, you can set which group to display in front. Click the group tab
No. that you want to display in front, and click OK.
Assigning Display Group Names
Enter the display group name in the Group Name box, and click OK.
The name is applied to the title of the display group tab of the window.
For each waveform, you can set the items shown in the following table.
Item Description
No. Show or hide each waveform
Channel Channel to assign to the waveform
Y-axis No. Y-axis to share between waveforms
Y-axis mode Display mode (detail, compact)
Y-axis type Scale display (linear, logarithmic)
Y-axis title Title
Display Display format for Y-axis scale values and data (normal, exponential)
Scale minimum Minimum value on the Y-axis scale
Scale maximum Maximum value on the Y-axis scale
Zone minimum Lower limit position for Y-axis display
Zone maximum Upper limit position for Y-axis display
Trip 1 to 4 usage Whether to use trip 1
Trip 1 to 4 values Trip 1 value
Trip 1 to 4 colors Trip 1 color
Grid line spacing usage Whether to set the grid line spacing
Grid line spacing Value to use for grid line spacing
Colors Waveform display color
Turning Waveform Displays On and Off
To display a waveform, select the waveform number check box. To hide it, clear the check
box. Click OK to apply the setting to the d”splay window.
Registering Channels
You can assign channels to waveforms.
Click the channel cell of a waveform that you want to edit. The Channel dialog box opens.
Select the channel to assign to the waveform. The result is applied to the Display Group
Setting dialog box. To not assign a channel, select None.
3.1 Displaying Waveforms