User guide
2-17
IM 04L51B01-17EN
Commands and Responses
1
2
App
Description
• The RGB values for different colors are indicated in
the following table.
Color R G B Note
Red 255 0 0
Green 0 153 51
Blue 0 51 255
Blue violet 119 51 204 GX10/GP10
102 51 204 GX20/GP20
Brown 153 51 0
Orange 255 153 51
Yellow green 153 204 51 GX10/GP10
170 221 51 GX20/GP20
Light blue 119 170 221 GX10/GP10
153 204 255 GX20/GP20
Violet 204 102 204 GX10/GP10
221 153 221 GX20/GP20
Gray 153 153 153
Lime 102 255 0
Cyan 0 255 255
Dark blue 0 0 153
Yellow 255 255 0
Light gray 204 204 204
Purple 153 0 153 GX10/GP10
136 0 136 GX20/GP20
Black 0 0 0
Pink 255 17 153
Rosy brown 204 153 153
Pale green 153 255 153 GX10/GP10
187 255 153 GX20/GP20
Dark gray 102 102 102
Olive 153 153 0
Dark cyan 0 153 153
Spring green 0 204 153 GX10/GP10
0 221 119 GX20/GP20
SZoneIO
Waveform Display Zone
Sets the waveform display zone of an AI, DI, or DO
channel.
Syntax
SZoneIO,p1,p2,p3
p1
Channel number
p2
Zone lower limit [%] (0 to 95)
p3
Zone upper limit [%] (5 to 100)
Query
SZoneIO[,p1]?
Example Set the waveform zone of channel 0001
waveform to 0% to 30%.
SZoneIO,0001,0,30
SScaleIO
Scale Display
Sets the scale display of an AI, DI, or DO channel.
Syntax
SScaleIO,p1,p2,p3
p1
Channel number
p2
Scale display position (Off, 1 to 10)
p3
Number of scale divisions (4 to 12, C10)
Query
SScaleIO[,p1]?
Example Display the channel 0001 scale at display
position 1. Display four equally spaced main
scale marks.
SScaleIO,0001,1,4
SBarIO
Bar Graph Display
Sets the bar graph display of an AI, DI, or DO channel.
Syntax
SBarIO,p1,p2,p3
p1
Channel number
p2
Bar display base position
Lower
Lower
Center
Center
Upper
Upper
p3
Number of scale divisions (4 to 12)
Query
SBarIO[,p1]?
Example Display the measured values of channel 0001
on a bar graph with the center set as the base
position (Center). Display four equally spaced
main scale marks.
SBarIO,0001,Center,4
SPartialIO
Partial Expanded Display
Sets the partial expanded display of an AI channel
waveform.
Syntax
SPartialIO,p1,p2,p3,p4
p1
Channel number
p2
Partial expanded On/Off (On, Off)
p3
Partial expanded boundary position [%] (1
to 99)
P4
Partial expanded boundary value (span
lower limit + 1 digit to span upper limit - 1
digit)
Query
SPartialIO[,p1]?
Example For channel 0001 whose measurement range
is 0 to 1.0000 V, display the measured value of
0.7500 V at the 50% position.
SPartialIO,0001,On,50,7500
Description
• You cannot set this on a “Skip” channel. p2 is fixed to
Off.
• If p2=Off, you cannot set p3 or subsequent
parameters.
• P2=On can be specified when the difference between
the span upper and lower limits is 2 digits or greater.
SBandIO
Color Scale Band
Sets the color scale band of an AI channel.
Syntax
SBandIO,p1,p2,p3,p4,p5,p6,p7
p1
Channel number
p2
Color scale band (Off, In, Out)
p3
R value of the color scale band RGB
colors (0 to 255)
P4
G value of the color scale band RGB
colors (0 to 255)
p5
B value of the color scale band RGB
colors (0 to 255)
p6
Upper limit of the color scale band display
(span lower limit to span upper limit)
2.4 Setting Commands