Owner's manual

1-42
IM MW100-17E
1.8 Output Commands
Example Output the decimal place and units of the channels 1 to
5.
FE1,001,005
Explanation Set a first and last channel number so that the first is
less than or equal to the last.
FF Output of Measured/Computed
FIFO Data
Setting When p1=0
FFp1,p2,p3,p4,p5,p6,p7<terminator>
When p1=1
FFp1,p2<terminator>
p1
Output type
0 Outputs the FIFO data
1 Outputs the FIFO read range
p2 Measurement groups
1 Data from measurement groups 1
2 Data from measurement groups 2
3 Data from measurement groups 3
p3 First channel (001 to 060 and A001 to
A300)
p4 Last channel (001 to 060 and A001 to
A300)
p5 Read out start position
(-1, 1 to 99999999999)
-1 Latest read position
p6
Read out end position
(-1, 1 to 99999999999)
-1 Latest read position
p7
Max. number of read blocks (1 to
9999)
Example Output the FIFO read range for measurement group 1.
FF1,1
Explanation
The oldest FIFO buffer data is overwritten with the
newest data in a cyclical manner
.
The output value of p1=1 (output FIFO read range)
is the allowable read range for p1=0 (FIFO data
output).
Set a first and last channel number so that the first is
less than or equal to the last.
FL Output of Logs, Alarm
Summaries, and Status
Setting
When p1=0
FLp1,p2,p3<terminator>
When p1=1
FLp1,p2,p3,p4<terminator>
When Outputting Logs
Setting
FLp1,p2,p3<terminator>
p1 Output type (0)
0 Log output
p2 Data type
ERROR Operation error log
RECORD Recording log
ALARM Alarm summary
MESSAGE Message summary
COM General purpose
communication log
FTP_C FTP client log
SMTP Mail client log
DHCP DHCP client log
SNTP Time synchronization
client log
FTP_S
FTP server log
HTTP HTTP server log
MODBUS_M Modbus master log
MODBUS_C Modbus client log
MODBUS_S Modbus slave log
MODBUS_T Modbus server log
CIP CIP server log
PCCC PCCC slave log
*
MATH Computation status
*
CMD Operation log
RECSTATUS Recording status
* Firmware version R3.02 or later
p3 Max. number of read blocks
ERROR 1 to 50
RECORD 1 to 250 (Or "1024" on
models with firmware version R3.02 or
earlier)
ALARM 1 to 256
MESSAGE 1 to 50
COM 1 to 200
FTP_C 1 to 50
SMTP 1 to 50
DHCP 1 to 50
SNTP 1 to 50
FTP_S 1 to 50
HTTP 1 to 50
MODBUS_M 1 to 50
MODBUS_C 1 to 50
MODBUS_S 1 to 50
MODBUS_T 1 to 50
CIP 1 to 50
*
PCCC 1 to 50
*
MATH 1
CMD 1 to 256
RECSTATUS 1
* Firmware version R3.02 or later
Example
Output 10 blocs of the operation error log.
FL0,ERROR,10
Explanation Outputs the log (records) saved to the instrument.
When Outputting Status
Setting
FLp1,p2,p3,p4<terminator>
p1 Output type (1)
1 Outputs status