Owner's manual

1-39
IM MW100-17E
Commands
1
2
3
AppApp
Index
STOP2 STOP key (equivalent to
holding down for 2 sec)
USER1 USER1 key
USER2 USER2 key
Example Executes the START key.
KISTART1
CE Error Display Clear
Setting
CEp1<terminator>
p1 Clears the error display (0)
Example Clears the error on the 7SEG display.
CE0
AK Alarm Acknowledgment
Setting
AKp1<terminator>
p1 Check alarm status, and make
notification (0) of output clear
command for alarm relay output hold
status
Example
Check alarm status, and make notification of output
clear command for alarm relay output hold status.
AK0
IR Timer Reset
Setting
IRp1<terminator>
p1 Number of timer
0 Reset all timers
1-6 Reset the specified timer
Example Reset all timers.
IR0
CM Communication Input Data
Settings
Setting
CMp1,p2<terminator>
p1 Communication input channel range
(C001 to C300)
p2 Communication input value
+INT (-
)
-INF (+
)
NAN (Not a Number)
-9.9999E+29 to -1.0000E-30
0
1.0000E-30 to 9.9999E+29
Query
CM[p1]?
Example Set a communication input value of 1.0000E-10 to
communication input channel C001.
CMC001,1.0000E-10
Explanation
See section 1.3 for the communication input value.
VD Relay ON/OFF
Setting
VDp1,p2<terminator>
p1 Relay range (001 to 060)
p2 Relay status (OFF/ON)
Example Turns the channel 1 relay ON.
VD001,ON
Explanation Valid only for the relay whose relay output type is set to
manual DO (COM) with the XD command.
SD Date and Time Settings
Setting
SDp1,p2,p3<terminator>
p1 Date (YY/MM/DD)
YY Year (80 to 99, 00 to 35)
MM Month (01 to 12)
DD Day (01 to 31)
p2 Time (HH:MM:SS)
HH hours (00 to 23)
MM Minute (00 to 59)
SS Seconds (00 to 59)
p3 Timezone (SHH:MM)
S Symbol (+/-)
HH hours (00 to 23)
MM Minute (00 to 59)
Query
SD?
Example Sets the MW100’s internal time to April 1, 2005,
13:00:00.
The time zone is 9:00.
SD05/04/01,13:00:00,+09:00
Explanation
The positive time zone symbol can be omitted.
RC Initialization of Settings
Setting
RCp1<terminator>
p1 Initialization level
0 Initialize all settings except
the module recognition
1 Initialize settings excluding
the following items
·
IP address, host name, subnet
mask, default gateway
·
Items relating to DHCP
· Items relating to DNS
· Items relating to
communication timeout
·
Items relating to login
function
·
Baud rate, parity bit, stop
bit, data length, handshaking,
and module recognition
information
Example Initialize all settings.
RC0
Explanation The communication settings are the parameters set
using YS, Y
A, YD, YN, YH, UA, and YQ.
1.7 Control Commands