Owner's manual

1-3
IM MW100-17E
Commands
1
2
3
AppApp
Index
1.2 List of Commands
Setting Commands (System Related)
Command Functions Operation Administrator User Page
Name Mode
SR
Input Range Settings Setting Y
es No 1-16
SF
Filter Settings Setting Y
es No 1-17
XB
Burnout Settings Setting Y
es No 1-17
XJ
Reference Junction Compensation Settings Setting Y
es No 1-17
PF
Pulse Input Module Chattering Filter Settings Setting Y
es No 1-17
SA
Alarm Settings All modes Y
es No 1-18
VA
Alarm Hysteresis Settings All modes Y
es No 1-18
XA
Settings Related to Alarm Setting
Yes No 1-18
BD
Delay Alarm Settings Setting
Yes No 1-19
XD
Relay Settings Setting Y
es No 1-19
SO
Expression Settings Setting Y
es No 1-19
SK
MATH Constant Settings Setting
Yes No 1-20
MG
MATH Group Settings Setting
Yes No 1-20
RO
Report Operation and Creation Time Settings
Setting Yes No 1-20
RM
Report Execution Channel Settings Setting Y
es No 1-20
VL
Broken-Line Input Channel Settings Setting Y
es No 1-21
AO
Output Range Settings Setting Y
es No 1-21
AP
Preset Operation Settings Setting Y
es No 1-22
SL
Event/Action Settings
Setting Yes No 1-22
SI
Timer Settings Setting
Yes No 1-24
SQ
Match Time Settings
Setting Yes No 1-24
XV
Measurement Interval Settings Setting Y
es No 1-25
XI
Measurement Groups and A/D Integration T
ime Settings Setting Yes No 1-25
VM
MATH Interval Settings Setting
Yes No 1-25
XG
Settings of Operation upon MATH Error Setting
Yes No 1-25
MC
File Message Settings Setting Y
es No 1-26
MD
Data Save Folder Settings Setting Y
es No 1-26
MH
Recording Channel Settings Setting Y
es No 1-27
MW
Recording Operation Settings Setting Y
es No 1-27
ML
Recording Data Length Settings Setting Y
es No 1-28
MR
Recording Free Space Settings Setting Y
es No 1-28
MX
Thinning Recording Operation Settings Setting Y
es No 1-28
MU
Setting Save Operation Settings Setting Y
es No 1-28
XK
Key Lock Settings All modes Y
es No 1-28
XT
Temperature Unit Settings Setting
Yes No 1-29
SW
Daylight Saving Time Settings
Setting Yes No 1-29
SS
Daylight Saving Time Operation Settings
Setting Yes No 1-29
BA
Settings of Strain Input Initial Balancing Setting Y
es No 1-29
UN
Unit Number Settings
Setting Yes No 1-29
SV
Rolling Average Settings
Setting Yes No 1-29
Yes: Permitted to use command, No: Not permitted to use command
Note
The instrument has two operation modes. If a command intended for use in one mode
is executed while in a different mode, an error results. Switch to the proper mode before
executing the command. Queries can be used regardless of the mode.
• Setting Mode
In this mode, measurement, computation, and recording is stopped, and settings can be
changed.
Measurement Mode
Computation and recording can be executed during measurement.
The administrator and user distinction shows the user level specified on the instrument’
s communication login function. For details, see the MW100 Data Acquisition Unit Users
Manual (IM MW100-01E).
Queries can be executed by both administrator and users.