Action Notation Detection Method
Edge Level
Write free message Free Message
Write message Message1
on specified number Message2
Message3
Message4
Message5
Save specified file
*2
File Save
Load specified file
*2
File Load
Perform manual sample
*1
Manual Sample
Divide manual sample file
*1
Manual Divide
*1 Cannot be selected when the event is Recording start.
*2 Can be selected when the event is User function key. The name of the target file is fixed to
SETTING.PNL.
Conditions in which actions do not execute
Depending on the state of the MW100, actions may not be executed even when events
occur.
Action Conditions
Recording start/recording stop Recording conditions are not valid. (Example:
no data to record)
Measurement paused.
Trigger occurrence recording paused.
Computation start/computation stop Computation conditions are not valid. (Example:
no valid equation)
Measurement paused.
Reset computation/clear computation Measurement paused.
*
Reset MATH on specified MATH group number Measurement paused.
*
Reset timer Measurement paused.
*
Alarm ACK Measurement paused.
*
Flag Measurement paused.
*
Write message Measurement paused.
Load specified file/save specified file Measurement is in progress.
Save recorded data in divisions Divide recording conditions are not valid.
(Example: recording paused)
Perform manual sample Measurement paused.
Divide manual sample file Measurement paused.
* These actions can be executed when the event runs with a user function key.
Even aside from the conditions above, in the case of conditions in which the function
does not run when instigated from a key operation, Web setting, or communication
command, the function (action) is not executed.