Instruction Manual
IM 1M12A01-03E
x
5.8 Wiring for Contact Input............................................................................... 5-15
5.8.1 Cable Specifications .............................................................................. 5-15
5.8.2 Wiring Procedure................................................................................... 5-15
5.9 Temperature Input Wiring ............................................................................ 5-16
5.9.1 Applicable Temperature Transmitter .................................................... 5-16
5.9.2 Cable Specifications .............................................................................. 5-16
5.9.3 Wiring Procedure................................................................................... 5-16
6. Components ................................................................................................................. 6-1
6.1 ZR22G Detector .............................................................................................. 6-1
6.1.1 General-purpose Detector ........................................................................ 6-1
6.2 ZR402G Converter .......................................................................................... 6-2
6.3 ZA8F Flow Setting Unit, ZR40H Automatic Calibration Unit ..................... 6-3
7. Startup.......................................................................................................................... 7-1
7.1 Checking Piping and Wiring Connections ..................................................... 7-1
7.2 Checking Valve Setup..................................................................................... 7-1
7.3 Supplying Power to the Converter.................................................................. 7-2
7.4 Touchpanel Switch Operations ....................................................................... 7-3
7.4.1 Basic Panel and Switch ........................................................................... 7-3
7.4.2 Display Configuration (for High-temperature Humidity Analyzer) ....... 7-4
7.4.3 Display Functions .................................................................................... 7-5
7.4.4 Entering Numeric and Text Data ............................................................ 7-5
7.5 Confirmation of Converter Type Setting ........................................................ 7-7
7.6 Confirmation of Detector Type Setting .......................................................... 7-8
7.7 Current Output Setting .................................................................................... 7-8
7.7.1 Analog Output Setting ............................................................................. 7-8
7.7.2 Minimum Current (4 mA) and Maximum Current (20 mA) Settings ... 7-9
7.8 Setting Display Item ..................................................................................... 7-10
7.9 Checking Current Loop................................................................................. 7-12
7.10 Checking Contact I/O ................................................................................... 7-13
7.10.1 Checking Contact Output ...................................................................... 7-13
7.10.2 Checking Calibration Contact Output ................................................... 7-14
7.10.3 Checking Input Contacts ....................................................................... 7-14
7.11 Calibration ..................................................................................................... 7-15
7.11.1 Calibration Setup ................................................................................... 7-15
7.11.2 Manual Calibration ................................................................................ 7-16
8. Detailed Data Setting .................................................................................................. 8-1
8.1 Current Output Setting .................................................................................... 8-1
8.1.1 About Input Ranges ................................................................................. 8-1
8.1.2 Setting Minimum Current (4 mA) and Maximum Current (20 mA) ..... 8-4
8.1.3 Entering Output Damping Constants ...................................................... 8-4
8.1.4 Selection of Output Mode ....................................................................... 8-4
8.1.5 Default Values ......................................................................................... 8-5
8.2 Output Hold Setting ........................................................................................ 8-6
8.2.1 Definition of Equipment Status............................................................... 8-6
8.2.2 Preference Order of Output Hold Value ................................................. 8-7
8.2.3 Output Hold Setting................................................................................. 8-8
8.2.4 Default Values ......................................................................................... 8-8