2. General Specifications
2.1 Specifications WU10-V-
WU10-V-S-..-.. WU10-V-D-..-..
Description Multicore shielded cable with one Multicore shielded cable with two
low noise coax and three insulated low noise coaxes and four
wires insulated wires
Max. Temperature 90°C continuously and 105°C continuously
105°C for max. 1000 hr and 125°C for max. 3000 hr
Sheath PVC ThermoplasticRubbersheath
copper stabilized
Colour Black Black
Diameter 6,5 mm 7 mm
Internalinsulation HDPE(Polyethylene) ThermoplasticRubbersheath
copper stabilized
Isolationresistance >1,5*1013OhmbetweenE,F >1,5*1013OhmbetweenE,
andoverallshield F,G,Handoverallshield
>0,5*1013Ohmbetweenblack
wire and overall shield
>1,5*1014OhmbetweenAand
overallshield >1,5*1014Ohm
between A and overall shield
Capacity <100pF/mbetweenA <90pF/mbetweenA,C
and overall shield and overall shield
<120pF/mbetweenAandB <120pF/mbetweenAandB
and between C and D
<350pF/mbetweenB <350pF/mbetweenB,D
and overall shield and overall shield
Resistance <100kOhm/kmforA <100kOhm/kmforAandC
<45kOhm/kmforwireC,EandF <45kOhm/kmforwireC,EandF
<100kOhm/kmforwireD <100kOhm/kmforwireD
Coaxialcable Brown;ThermoplasticRubber BrownorwhiteThermoplastic
sheath Rubbersheathcopperstabilized
After termination core lead insulation After termination core lead
transparent and shield insulated insulation transparent and shield
with brown cover insulated with brown or white cover
Diameter 3,3 mm Diameter 2,7 mm
Wire D Bare drain wire covered with yellow
insulation after termination
(overall shield)
Wire C Black cover diameter 1,2 mm
WireE Redcoverdiameter1,5mm Redcoverdiameter1,4mm
WireF Bluecoverdiameter1,5mm Bluecoverdiamter1,4mm
WireG n/a Yellowcoverdiamter1,4mm
WireH n/a Greencoverdiamter1,4mm
Table 1: Flame retardant in accordance to IEC 60332-1
Ingress protection in accordance with IP67