Owner's manual

IM 01R04B08-00E-E 1st edition February 15, 2012 -00
All Rights Reserved. Copyright © 2012, Rota Yokogawa
<10. GENERAL SPECIFICATIONS>
10-4
Remote rack-mount Converter RCCR31, Model, Suffix and Option Code
Model Suffix Code Option
Code
Description Restrictions
RCCR31 Remoteconverterfor19´´rackmountingtobeconnectedtoRCCS3
Power supply -A
-D
90-264VAC
24VDC
HazardousAreaApprovals
1)
/KS1
/FS1
/ES1
/US1
ATEXassociatedapparatusforintrinsicsafedetectorconnectionforgasgroupIIC
FM associated apparatus for intrinsic safe detector
output
IECEx associated apparatus for intrinsic safe detector output for gas group IIC
INMETROassociatedapparatusforintrinsicsafedetectoroutputforgasgroupIIC
with /HP for gas group IIB
with/HPnotforgasgroupsAandB
with /HP for gas group IIB
with /HP for gas group IIB
GOST
1)
/QR1
/QR2
PrimaryCalibrationandTestConrmationvalidinRussia
PrimaryCalibrationandTestConrmationvalidinKazakhstan
see page 9
see page 9
HighDrivingPower /HP HighDrivingPower not for combination with RCCS30 to 34, recom-
mended for combination with RCCS36 to 39,
strongly recommended for combination with
RCCS39/IR, mandatory for combination with
RCCS39/XR
ActivePulseOutput /AP Oneactivepulseoutput notwith/NM
NAMURSwitch /NM Onepulseoutputacc.EN60947-5-6(NAMUR) notwith/AP
Communication /MB1 Modbuscommunicationprotocolforselectedparametersandvalues notwith/AP
TagNumber /BG With customer specied tag number on name plate max. 16 digits
HARTTagNumber(SoftwareTag) /BT1 WithcustomerspeciedtagnumberforHARTcommunicationinconverter 8 digits for tag, 22 digits for long tag
Gas Measurement /GA Gas measurement, special factory adjustments and settings selectaffiliatedRCCS3with/GA
Combination with RCCS39/XR /XR SpecialconverteradjustmentwithRCCS39/XR mandatory for combination with RCCS39/XR
NoCombination /NC Nocombinationwithdetector
Customer Presetting /PS Presetting sheet with customer data has to be issued with the order
Concentration Measurement
2)
/CST
/Cxx
Standard concentration measurement
Advancedconcentrationmeasurement,detailsseetable„AdvancedConcentration
Measurement Options“
Subrack /SR2
/SR4
Subrackfor2converterRCCR31withmounting
Subrackfor4converterRCCR31withmounting
DeliverytoKorea /KC With KC-mark for Korea
Instruction Manuals /IEn
/IDn
/IFn
Quantity of instruction manuals in English
Quantity of instruction manuals in German
Quantity of instruction manuals in French
n=1to3selectable
3)
n=1to3selectable
3)
n=1to3selectable
3)
Special order /Z Special design must be specication an extra sheet
1)
SelectaffiliatedRCCS3withthesameapprovaltype(e.g./KS1with/KS1).
2)
For detailed information please see TI 01R04B04-04E-E. Option /K6 of RCCS3 is recommended with concentration measurement.
3)