Instruction Manual


7-18
IM 01R04B04-00E-E 8th edition March 01, 2011 -00
All Rights Reserved. Copyright © 2003, Rota Yokogawa
 

 

 








Concentration meas format Select xxxxxxx - - R/W X xxxx.XX
xxxxx.X X
xxxx.XX X
xxx.XXX X
xx.XXXX X
x.XXXXX X
Concentration meas LRV Decimal 0 to 110 0 to 5
Concentration
meas unit
R/W X 0
Concentration meas URV Decimal 0 to 110 0 to 5
Concentration
meas unit
R/W X 100
Concentration meas Damp Decimal 0 to 200 1 Sec R/W X 10
Concentration meas lowcut Decimal 0 to 10% 0 to 5
Concentration
meas unit
R/W 0
Conc meas alm 1 sel Select No function - - R/W X No function
More than
Less than
Conc meas alm 1 crit Decimal 0 to 110% of URV 0 to 5
Concentration
meas unit
R/W X LRV
Conc meas alm 2 sel Select No function - - R/W X No function
More than
Less than
Conc meas alm 2 crit Decimal 0 to 110% of URV 0 to 5
Concentration
meas unit
R/W X URV
Net ow select Select Mass - - R/W X Mass
Volume